Single Screw Compressor PLC Operation Manual •Vilter/Emerson • 35391CM
Section 1 • General Information
Temperature of the compressor oil in the bottom of the
oil separator vessel.
Suction Oil Injection
Method of providing additional lubrication to large
frame compressors (models 2401-3001) at compressor
start.
Suction Pressure
Pressure of the refrigerant or gas measured at the inlet
of the compressor.
Suction Temperature
Temperature of the refrigerant or gas measured at the
inlet of the compressor.
Surge Drum or Suction Accumulator
Vessel where additional liquid refrigerant may accumu-
late to prevent liquid from getting into the compressor.
Temperature Transmitter
Device that measures temperature and transmits the
temperature reading as a 4-20mA signal. This 4-20mA
signal is read by the PLC and displayed as a temperature.
Trip
Compressor shutdown due to an abnormal process or
operational condition.
Venturi Oil Recovery
Method of recovering compressor oil from the chiller us-
ing solenoid valves on a cycle timer.
VFD
VFD stands for “Variable Frequency Drive.” A VFD is a
motor control device that can vary the speed of an AC
induction motor.
Volume Slide Valve
Internal mechanism in the compressor that controls the
amount of gas owing into the compressor.
Volume Slide Valve Actuator
Drive motor that moves the volume slide valve, and
gives feedback on the position of the volume slide valve.
V-PLUS
V-PLUS stands for “Vilter Pumped Liquid Unitary
System.” It is a method of oil cooling where liquid refrig-
erant is pumped into the discharge line or housing by a
variable speed pump.
Outlet Scrubber Outlet Pressure
Pressure of gas measured at the outlet of the outlet
scrubber.
Outlet Scrubber Pressure Drop
Pressure differential between inlet and outlet of the out-
let scrubber. Calculated: Scrubber Inlet Pressure minus
Scrubber Outlet Pressure.
PID Controller
PID stands for “Proportional Integral Derivative.” A PID
controller manipulates a control variable (example: valve
position or fan/pump speed) to maintain a process vari-
able (example: process temperature or pressure) at a de-
sired value (setpoint). The controller is driven by math-
ematical calculations that tell the control variable how to
react to changes in the process variable.
PLC
PLC stands for “Programmable Logic Controller.” The
Compressor PLC is an industrial computer that controls
the compressor unit or Package.
Prelube Oil Pressure Calculated
Oil Filter Outlet (Manifold) Pressure minus Discharge
Pressure. Monitored at compressor start to ensure ad-
equate lubrication.
Pressure Ratio
The ratio of compressor discharge pressure to suction
pressure.
Pressure Ratio Calculated
(Discharge Pressure) / (Suction Pressure)
Pressure Transducer or Transmitter
Device that measures pressure and transmits the pres-
sure reading as a 4-20mA signal. This 4-20mA signal is
read by the PLC and displayed as a pressure.
Process Temperature
Temperature of the process uid (liquid or gas, ex. natu-
ral gas, glycol, water) measured at the process outlet of
the chiller.
RTD
RTD stands for “Resistance Temperature Detector.
RTDs use electrical resistance to measure temperature.
This resistance is read by the PLC and displayed as a
temperature.
Separator Oil Temperature