Page view 154
12 – 21
Section 12 • Communications with a Central Controller/DCS
Single Screw Compressor PLC Operation Manual • Vilter/Emerson • 35391CM
Interface Tag Description
BOOL_OUT[32].1 Condenser Fan Aux Contact (Step Type)
BOOL_OUT[32].2 Condenser Fan Aux Contact (Step Type)
BOOL_OUT[32].3 Condenser Fan Aux Contact (Step Type)
BOOL_OUT[32].4 Evap Condenser Pump Running
BOOL_OUT[32].5 Condenser VFD Faulted (VFD Type)
BOOL_OUT[32].6 Condenser VFD Running
BOOL_OUT[32].7 E-stop OK and MCR energized
BOOL_OUT[32].8 NOT USED
BOOL_OUT[32].9 NOT USED
BOOL_OUT[32].10 Inlet Scrubber Condensate Pump Aux Contact
BOOL_OUT[32].11 Inlet Scrubber Condensate Pump Aux Contact
BOOL_OUT[32].12 Lower Inlet Scrubber High Alarm (Coalescing)
BOOL_OUT[32].13 Lower Inlet Scrubber High Trip (Coalescing)
BOOL_OUT[32].14 Upper Inlet Scrubber High Alarm (Coalescing)
BOOL_OUT[32].15 Upper Inlet Scrubber High Trip (Coalescing)
BOOL_OUT[32].16 Inlet Scrubber Condensate Drain Cutin Switch
BOOL_OUT[32].17 Inlet Scrubber Condensate Drain Cutout Switch
BOOL_OUT[32].18 Inlet Scrubber High Alarm (Vane type)
BOOL_OUT[32].19 Inlet Scrubber High Trip (Vane Type)
BOOL_OUT[32].20 Inlet Scrubber Low Level (Vane Type)
BOOL_OUT[32].21 Compressor Main Motor Aux Contact
BOOL_OUT[32].22 Compressor Main Motor Fault
BOOL_OUT[32].23 Main Motor Cooling Blower Running
BOOL_OUT[32].24 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].25 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].26 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].27 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].28 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].29 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].30 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[32].31 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[33].0 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[33].1 Oil Cooler Fan Aux Contact (Step Type)
BOOL_OUT[33].2 Oil Cooler VFD Faulted (VFD Type)
BOOL_OUT[33].3 Oil Cooler VFD Running
BOOL_OUT[33].4 Oil Recovery Enable Switch
BOOL_OUT[33].5 Oil Separator Low Level Switch
BOOL_OUT[33].6 Outlet Scrubber Condensate Pump Aux Contact
BOOL_OUT[33].7 Outlet Scrubber Condensate Pump Aux Contact
BOOL_OUT[33].8 Lower Outlet Scrubber High Alarm (Coalescing)
BOOL_OUT[33].9 Lower Outlet Scrubber High Trip (Coalescing)
Page view 154