www.emersonprocess.com/rosemountReference Manual00809-0100-4001, Rev JANovember 2012Rosemount 3051 Pressure Transmitterwith HART® Protocol
xReference Manual00809-0100-4001, Rev JATable of ContentsNovember 2012Table of Contents
90Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.2.1 Warnings ( )Explosions could result in death or s
91Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingTable 5-1. Rosemount 3051 troubleshooting table for 4
92Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.3 Diagnostic messagesIn addition to the output, the L
93Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingPress LimitThe process variable read by the transmitte
94Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingSpan FailThe span value, set with the local span adjust
95Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting4k snsr EEPROMerror-factory ONReplace the transmitter.
96Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingLooking for a device Polling for multidropped devices a
97Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.4 Disassembly proceduresDo not remove the instrument
98Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.4.1 Remove from serviceFollow these steps: Follow al
99Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.4.2 Remove terminal blockElectrical connections are
Reference Manual 00809-0100-4001, Rev JASection 1: IntroductionNovember 20121IntroductionSection 1 Introduction1.1 Using this manualThe sections in th
100Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingNoteDo not remove the housing until after you tuck the
101Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012Troubleshooting5.5.2 Install the terminal block1. Gently slide the t
102Reference Manual00809-0100-4001, Rev JASection 5: TroubleshootingNovember 2012TroubleshootingTable 5-3. Bolt installation torque valuesNoteIf you
Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012103Specifications and reference dataAppendix A Specifications and refer
104Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.1.2 Reference accuracy(1)A.1.3 Tot
105Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.1.4 Long term stabilityA.1.5 Dyna
106Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.1.7 Ambient temperature effect per
107Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.1.10 Power supply effectLess than
108Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.2 Functional specificationsA.2.1 R
109Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-2. 3051CD, 3051CG, 3051L,
2Reference Manual00809-0100-4001, Rev JASection 1: IntroductionNovember 2012IntroductionEmerson Process Management Instrument and Valve Response Cente
110Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.2.3 ServiceLiquid, gas, and vapor
111Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.2.6 FOUNDATION fieldbus function
112Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.2.9 Backup Link Active Scheduler (
113Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataMinimum Load Impedance100 k (Vout
114Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-4. 3051L and level flange r
115Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataOutput Code F and WIf self-diagnost
116Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataHumidity Limits0–100% relative humid
117Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataRosemount 3051LHigh pressure side:
118Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.3.4 Rosemount 3051L Process Wetted
119Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataPaintPolyurethaneCover O-ringsBuna-
3Reference Manual 00809-0100-4001, Rev JASection 1: IntroductionNovember 2012IntroductionNoteFor Rosemount 3051 with FOUNDATION™ fieldbus, see Rosemou
120Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.4 Dimensional Drawings3051 Explode
121Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051C Coplanar Flange3051C Coplanar
122Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataCoplanar Flange Mounting Configurati
123Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051C Coplanar with Traditional Fla
124Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTraditional Flange Mounting Configur
125Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051T Dimensional Drawings3051T wit
126Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051T Typical Mounting Configuration
127Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data 3051L Dimensional Drawings2-in. Fl
128Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data(1) Tolerances are 0.040 (1,02), –0.
129Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051H Pressure Transmitter Exploded
4Reference Manual00809-0100-4001, Rev JASection 1: IntroductionNovember 2012IntroductionFigure 1-1. Block diagram of operation 1.5 Product recycling/
130Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data3051H Mounting Brackets for 2-in. Pi
131Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.5 Ordering InformationModel Trans
132Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataMaterials of ConstructionProcess Fla
133Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataExpandedD Polyurethane-covered Alum
134Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataIntegral Mount Primary ElementStanda
135Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataE3 China Flameproof ★E4(12)TIIS Fla
136Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataCalibration CertificateStandard Stan
137Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataPressure TestingExpandedP1 Hydrosta
138Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataGround ScrewStandard StandardV5(12)E
139Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataPressure Upper Range Limit - Config
Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 20125InstallationSection 2 InstallationOverview . . . . . . . . . . . . . . .
140Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataHousing Material Conduit Entry SizeS
141Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataE5 FM Explosion-proof, Dust Ignitio
142Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataZero/Span AdjustmentStandard Standar
143Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataCleaning Process AreaExpandedP2 Cle
144Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataModel Transmitter Type3051L Liquid L
145Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataD4(3)4-in./DN 100 Alloy C-276 4-in.
146Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data5(3)— 20K per JIS B2238 316 SST6(3)—
147Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataExpandedD Aluminum G½M SST G½A.5.3
148Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataI7(5)IECEx Intrinsic Safety ★E7(5)IE
149Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataToolkit Total System Performance Re
6Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.3 General considerationsMeasurement accuracy depends upon pr
150Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataLower Housing Flushing Connection Op
151Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataM(1)Low-Power, 1–5 Vdc with Digital
152Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.5.4 Options (Include with selected
153Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataN7 IECEx Type n Certification • •E2
154Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataCode Alarm Limit HD HGExpandedC4(5)(
155Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataCode A Number Specials HD HGExpande
156Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.6 OptionsStandard ConfigurationUnl
157Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTagging (3 options available) Stan
158Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataLocal Span and Zero Adjustment(1)Tra
159Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataB2 Bracket for Panel Mounting For
7Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationImportantInstall the enclosed pipe plug (found in the box) in
160Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-7. 3051L weights without op
161Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-9. 3051C differential/gage
162Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-10. 3051L/3051H pressure t
163Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTable A-12. 3051T gage and absolut
164Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataA.7 Spare partsModel 3051C Sensor Mo
165Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data–2000 to 2000/20 psi, Range 5316L S
166Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataRange 4 –14.2 to 300 psi/3 psi -300
167Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataRange 4, 0 to 400 psia/40 psia316L
168Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataElectrical housings (without termina
169Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataGage/Absolute Coplanar Flange316 SS
8Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationAnother method is to plumb the reference side to a chamber tha
170Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataAlloy 400 adapters 03031-1300-0114Ni
171Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataTRADITIONAL FLANGEDifferential Flan
172Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataMounting brackets Part number3051C a
173Reference Manual 00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference dataFigure A-1. Spare parts diagramElec
174Reference Manual00809-0100-4001, Rev JAAppendix A: Reference DataNovember 2012Specifications and reference data
Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012175Product certificationsAppendix B Product certificationsOverv
176Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsB.2.1 WarningsB.3 Approved manufacturin
177Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsB.5 Hazardous locations certifications
178Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsEuropean certificationsE8 ATEX Flame-Pr
179Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsN1 ATEX Non-incendive/Type n and Dust
9Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.7 HART installation flowchartFigure 2-1. HART installation
180Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications2.) For information on the dimensions o
181Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsChina certificationsE3 Flameproof and
182Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsSpecific Conditions for Safe Use (X):1.
183Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsSpecific Conditions for Safe Use (X):1
184Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsB.6 Approval drawingsB.6.1 Factory mutu
185Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
186Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
187Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
188Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
189Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
10Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.8 Installation procedures2.8.1 Mount the transmitterFor dim
190Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
191Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
192Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
193Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
194Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
195Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
196Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
197Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certificationsB.6.2 Canadian standards association (
198Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
199Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
11Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationTable 2-1. Mounting bracketsFigure 2-2. Mounting bracket op
200Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
201Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
202Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
203Reference Manual 00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
204Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
205Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
206Reference Manual00809-0100-4001, Rev JAAppendix B: Product CertificationsNovember 2012Product certifications
Index-207Reference Manual 00809-0100-4001, Rev JAIndexNovember 2012IndexAAddressChanging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index-208Reference Manual00809-0100-4001, Rev JAIndexNovember 2012IndexDiagramsBench hook-up . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index-209Reference Manual 00809-0100-4001, Rev JAIndexNovember 2012IndexLow powerDiagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation4.09 (104)3.75 (95)1.63 (41)2.73 (69)4.97 (126)2.81 (71)1.63
Index-210Reference Manual00809-0100-4001, Rev JAIndexNovember 2012IndexTrimAnalog output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77D
Reference Manual00809-0100-4001, Rev JANovember 2012Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_saleThe Emerson l
13Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationBolt installationOnly use bolts supplied with the Rosemount
14Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-4. Traditional flange bolt configurationsFigure 2-7.
15Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installationfriction loss (particularly if purging is used), trapped gas
16Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationNoteFor steam or other elevated temperature services, it is i
17Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationWhenever you remove flanges or adapters, visually inspect th
18Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.8.4 Inline process connectionInline gage transmitter orient
19Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-11. Housing rotation2.8.6 LCD display Transmitters
Reference Manual 00809-0100-4001, Rev JATitle PageNovember 2012iiiRosemount 3051 Pressure TransmitterRead this manual before working with the product.
20Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.8.7 Configure security and alarmSecurity (write protect)The
21Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-13. Electronics boardFigure 2-14. Low power transmi
22Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.9 Electrical considerationsNoteMake sure all electrical ins
23Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.9.2 WiringNoteUse shielded twisted pairs to yield best res
24Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-17. 1-5 Vdc low power wiringPower SupplyVoltmeter
25Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationPerform the following procedure to make wiring connections:1
26Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationPower supply for 1-5 Vdc HART low powerLow power transmitters
27Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-20. 1-5 Vdc low power wiring with transient protect
28Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationSignal wiring Do not run signal wiring in conduit or open tra
29Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-23. External ground assemblyNoteGrounding the trans
ivReference Manual00809-0100-4001, Rev JATitle PageNovember 2012
30Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-24. Manifolds3051C AND 305 INTEGRAL COPLANAR 3051C A
31Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.11.1 Rosemount 305 integral manifold installation procedur
32Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationAlways perform a zero trim on the transmitter/manifold assemb
33Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFive-valve Natural Gas configurations shown:NoteDo not open
34Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.12 Liquid level measurementDifferential pressure transmitte
35Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012Installation2.12.1 Open vesselsA pressure transmitter mounted near a tan
36Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationDry leg conditionLow-side transmitter piping will remain empt
37Reference Manual 00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-26. Wet leg example.Let X equal the vertical distan
38Reference Manual00809-0100-4001, Rev JASection 2: InstallationNovember 2012InstallationFigure 2-27. Bubbler liquid level measurement example.mA dcLe
Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 201239ConfigurationSection 3 ConfigurationOverview . . . . . . . . . . . . .
vReference Manual 00809-0100-4001, Rev JATable of ContentsNovember 2012Table of Contents 1Section 1: Introduction1.1 Using this manual. . . . . . . .
40Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.3 CommissioningCommissioning consists of testing the tran
41Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.3.2 Wiring diagramsConnect the equipment as shown in Fig
42Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.4 Configuration data review NoteInformation and procedure
43Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.5.1 Field communicator user interfaceFigure 3-3. Traditi
44Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.6 Field communicator menu treesFigure 3-5. Rosemount 3051
45Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationFigure 3-6. Rosemount 3051 traditional HART menu tree for
46Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationFigure 3-7. Rosemount 3051 device dashboard menu tree - ove
47Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationFigure 3-8. Rosemount 3051 device dashboard menu tree - co
48Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationFigure 3-9. Rosemount 3051 device dashboard menu tree - ser
49Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationCustom Meter Value 1, 4, 3, 4, 3 N/A⻫ Damping 1, 3, 6 1, 3
viReference Manual00809-0100-4001, Rev JATable of ContentsNovember 2012Table of Contents2.12Liquid level measurement . . . . . . . . . . . . . . . . .
50Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationTable 3-2. 3051 device dashboard fast key sequence3.8 Chec
51Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.8.1 Process variablesThe process variables for the 3051
52Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.9 Basic setup3.9.1 Set process variable unitsThe PV Unit
53Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicatorAMS device manager Right click on the de
54Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationNoteTransmitters are shipped from Emerson Process Managemen
55Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicatorFrom the HOME screen, enter the fast key
56Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationAMS device managerRight click on the device, select Calibra
57Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationFigure 3-11. Zero and span buttonsNoteThe span is maintain
58Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicatorAMS device managerRight click on the devi
59Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.10.1 LCD display configuration for 4-20 mA HART onlyThe
viiReference Manual 00809-0100-4001, Rev JATable of ContentsNovember 2012Table of Contents3.15Changing a transmitter address . . . . . . . . . . . . .
60Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationTo configure the display with a Field Communicator, perform
61Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.11 Detailed setup3.11.1 Failure mode alarm and saturatio
62Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.11.2 Alarm and saturation levels for burst modeTransmitte
63Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicatorTo initiate a loop test, perform the fol
64Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationAMS device managerRight click on the device and select Diag
65Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicator1. Completely configure the first transm
66Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationNoteThe transmitter receiving cloned data must have the sam
67Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration1. Select the desired user configuration in the User Confi
68Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.14 Multidrop communication Multidropping transmitters ref
69Reference Manual 00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012Configuration3.15 Changing a transmitter addressTo activate multidrop c
viiiReference Manual00809-0100-4001, Rev JATable of ContentsNovember 2012Table of Contents5.5.4 Install the drain/vent valve . . . . . . . . . . . .
70Reference Manual00809-0100-4001, Rev JASection 3: ConfigurationNovember 2012ConfigurationField communicatorAMS device managerClick on the HART modem
Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 201271Operation and maintenanceSection 4 Operation and maintenan
72Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenance4.2.1 Warnings4.3 Calibration overv
73Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceFigure 4-1 on page 73 illustrates
74Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceTable 4-1. Recommended calibration
75Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenance1. Determine the performance requi
76Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceStep 2: Determine the operating con
77Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenancea. If the pressure reading does no
78Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenance1. From the HOME screen, enter the
79Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceAMS Device ManagerRight click on t
ixReference Manual 00809-0100-4001, Rev JATable of ContentsNovember 2012Table of ContentsA.3.4 Rosemount 3051L Process Wetted Parts . . . . . . . . .
80Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceAMS Device ManagerRight click on th
81Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceAMS Device ManagerRight click on t
82Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceFigure 4-3. Sensor trim4.5.2 Zero t
83Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenance4.5.3 Sensor trim NoteUse a pressu
84Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceAMS Device ManagerRight click on th
85Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceZero effectExample: Line pressure
86Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceExampleA Range 4 transmitter with m
87Reference Manual 00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenanceNoteThe range values for the 4 and
88Reference Manual00809-0100-4001, Rev JASection 4: Operation and MaintenanceNovember 2012Operation and maintenance
Reference Manual 00809-0100-4001, Rev JASection 5: TroubleshootingNovember 201289TroubleshootingSection 5 TroubleshootingOverview . . . . . . . . . .
Comments to this Manuals