Reference Manual
00809-0100-4001, Rev JA
Appendix A: Reference Data
November 2012
Specifications and reference data
Pressure Testing
Expanded
P1 Hydrostatic Testing with Certificate
Cleaning Process Area
Expanded
P2 Cleaning for Special Service
P3 Cleaning for <1 PPM Chlorine/Fluorine
Pressure Calibration
Expanded
P4 Calibrate at Line Pressure (Specify Q48 on order for corresponding certificate)
High Accuracy
Standard Standard
P8 0.04% accuracy to 5:1 turndown (Range 2-4)
Flange Adapters
Standard Standard
DF
1
/2 -14 NPT flange adapter(s)
D3 ¼–18 NPT Process Connections (No flange adapters), Hastelloy
D3 ¼–18 NPT Process Connections (No flange adapters), Monel
Vent/Drain Valves
Expanded
D7 Coplanar Flange Without Drain/Vent Ports
Conduit Plug
Standard Standard
DO 316 SST Conduit Plug
RC
1
/4 RC
1
/2 Process Connection
Expanded
D9 JIS Process Connection—RC ¼ Flange with RC ½ Flange Adapter, CS
D9 JIS Process Connection—RC ¼ Flange with RC ½ Flange Adapter, 316SST
Max Static Line Pressure
Standard Standard
P9 4500 psig Static Pressure Limit (3051CD Ranges 2–5 only)
Page view 146