143
Reference Manual
00809-0100-4001, Rev JA
Appendix A: Reference Data
November 2012
Specifications and reference data
Cleaning Process Area
Expanded
P2 Cleaning for Special Service
P3 Cleaning for <1 PPM Chlorine/Fluorine
High Accuracy
Standard Standard
P8 0.04% accuracy to 5:1 turndown (Range 2-4) ★
Ground Screw
Standard Standard
V5
(10)
External Ground Screw Assembly ★
Drinking Water Approval
Standard Standard
DW NSF drinking water approval ★
Surface Finish
Standard Standard
Q16 Surface finish certification for sanitary remote seals ★
Toolkit Total System Performance Reports
Standard Standard
QZ Remote Seal System Performance Calculation Report ★
Conduit Electrical Connector
Standard Standard
GE M12, 4-pin, Male Connector (eurofast
®
) ★
GM A size Mini, 4-pin, Male Connector (minifast
®
) ★
Typical Model Number: 3051T G 5 F 2A 2 1 A B4
(1) 3051TG lower range limit varies with atmospheric pressure.
(2) Option code M4 - LCD Display with Local Operator Interface required for local addressing and configuration.
(3) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to
certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(4) “Assemble-to” items are specified separately and require a completed model number.
(5) Not available with low-power Option Code M.
(6) Not available with fieldbus (output code F) or Profibus protocols (output code W).
(7) Local zero and span adjustments are standard unless Option Code J1 or J3 is specified.
(8) Available only with output code W - Profibus PA.
(9) NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
(10) The V5 option is not needed with T1 option; external ground screw assembly is included with the T1 option.