Emerson 3051S Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 222
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
116
Reference Manual
00809-0100-4001, Rev JA
Appendix A: Reference Data
November 2012
Specifications and reference data
Humidity Limits
0–100% relative humidity
Turn-On Time
Performance within specifications less than 2.0 seconds (10.0 s for Profibus protocol) after
power is applied to the transmitter
Volumetric Displacement
Less than 0.005 in
3
(0,08 cm
3
)
Damping
Analog output response to a step input change is user-selectable from 0 to 36 seconds for one
time constant. This software damping is in addition to sensor module response time.
A.3 Physical specifications
A.3.1 Electrical Connections
1
/2–14 NPT, G
1
/2, and M20 × 1.5 (CM20) conduit. HART interface connections fixed to terminal
block.
A.3.2 Process Connections
All Models except 3051L and 3051T
1
/4–18 NPT on 2
1
/8-in. centers
1
/2–14 NPT on 2-, 2
1
/8-, or 2
1
/4-in. centers
3051L high-side temperature limits (process fill fluid)
Syltherm
®
XLT –100 to 300 °F (–73 to 149 °C)
D.C. Silicone 704
®
32 to 400 °F (0 to 205 °C)
D.C. Silicone 200 –40 to 400 °F (–40 to 205 °C)
Inert –50 to 350 °F (–45 to 177 °C)
Glycerin and Water 0 to 200 °F (–18 to 93 °C)
Neobee M-20 0 to 400 °F (–18 to 205 °C)
Propylene Glycol and Water 0 to 200 °F (–18 to 93 °C)
(1) Process temperatures above 185 °F (85 °C) require derating the ambient limits by a 1.5:1 ratio
(0.6:1 ratio for the 3051H).
(2) 220 °F (104 °C) limit in vacuum service; 130 °F (54 °C) for pressures below 0.5 psia.
(3) 3051CD0 process temperature limits are –40 to 212 °F (–45 to 100 °C)
(4) 160 °F (71 °C) limit in vacuum service.
(5) Not available for 3051CA.
Page view 125