Emerson 1410 Service Manual Page 94

  • Download
  • Add to my manuals
  • Print
  • Page
    / 222
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 93
Configuring and Operating the System
AXP 1410 Installation and Use (6806800H70D)
94
shm9s8:~ # hpiship -n 8449 -i 200.200.0.0
5.2.4.3 Configuration File
By default, the shelf manager automatically reads the shelf IP connectivity record and
calculates IP addresses based on the described scheme.
Alternatively the shelf configuration for SGA and IP may be configured using the network
configuration file.
The network configuration of the SAM1410 can be modified by settings available in
/etc/network.conf. The /etc/network.conf file is part of the persistent file system
by default, so any changes are automatically saved across a reboot.
z Shelf Address
The Shelf Address can be read through IPMI or it can be defined as a different value by using
the SA variable.
Use auto to read the value via IPMI or define the desired Shelf Address.
SA=auto
z Slot Number
The slot number of the Shelf Manager is read via IPMI unless the SLOT variable is used to
override the value. Use auto to read the value via IPMI or define the desired slot number.
The REM_SLOT variable is the slot number of the other Shelf Manager.
SLOT=auto
REM_SLOT=auto
z Out-of-band Network Configuration
The front panel ethernet interface can be configured automatically using the Shelf Address
(default), using DHCP, or by specifying a static IP address.
Use the following parameters to the OOB_MODE variable to define the out-of-band
interface configuration.
none - Do not configure the interface
Page view 93