Emerson 1410 Service Manual Page 76

  • Download
  • Add to my manuals
  • Print
  • Page
    / 222
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 75
FRU Installation
AXP 1410 Installation and Use (6806800H70D)
76
Replacement Procedure
To replace the fan filter for a lower FTM, refer to Removing the Lower FTM and follow these steps
to replace a fan filter. Please have your replacement fan filter available before starting this
procedure.
1. With the FTM removed and placed on a solid surface, position the FTM with the
front facing you.
2. Using your fingers, rotate the filter frame away from the housing using the two tabs
on the right and left sides of the filter frame.
3. Rotate the vane assembly out of the way to expose the lower portion of the air filter.
4. Insert the replacement fan filter by positioning the filter onto the velcro edges and
form into place.
Any particulates that fall into the fan tray module during the air filter replacement must be
cleaned out (vacuumed) from the fan tray prior to re-installing the fan tray into the chassis.