Page view 74
FRU Installation
AXP 1410 Installation and Use (6806800H70D)
75
3. Open the ejector handle to a full open position.
4. Using the ejector handle on the front of the FTM, slowly pull the FTM out of the
shelf, while supporting the bottom of the module with the palm of your hand.
4.4.4 Installing the Lower FTM
Installation Procedure
Have the correct FTM available and follow these steps to install the upper fan tray module.
1. While supporting the FTM, align the FTM carefully into the fan slot in the shelf and
slowly slide the FTM until the ejector handles engage; fully close the handles.
The FTM is connected when the assembly is firmly seated in the upper backplane
connector and the hot swap handle moves to the closed position.
2. Tighten the chassis retention screw to secure the FTM. The recommended torque
settings is 5 inch-pounds.
When the blue LED turns off, the fan is operating.
4.5 Installing a Fan Filter
Your replacement fan filter consists of a filter media for the lower Fan Tray Module. The fan filter
housing is kept in place by two tabs located on the inner left-side in front of the stationary
metal frame.
Air filters should be checked occasionally to make sure they are not obstructed or damaged.
Visually inspect filters for tears or rips. Do not reinstall a torn filter as it will be ineffective in
trapping particulates and will interrupt air flow distribution. To maintain safety certification,
use only Emerson approved fan filters. You can order replacement fan filters by contacting your
Emerson sales representative.
The module is heavy; hold it securely.
Page view 74