FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
162
7.3.5.3 Temperature Sensor
The following tables describe the temperature sensor available on the PEMs.
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Upper Non-Critical, Critical and Non-
Recoverable Thresholds are Readable and
Settable
Reading Type Unsigned
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0xB4, 0xB8, 0xBE (75, 77, 80) Amps
Table 7-47 Sensor No. 16 Current Measure2 (continued)
Feature Raw Value/Description Interpreted Value
Table 7-48 Sensor No. 12 LM73 Temp
Feature Raw Value/Description Interpreted Value
Sensor Name LM73 Temp
Device
Sensor Type 0x01 Temperature
Class 0x01 Threshold
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm mode Auto
Hysteresis support Readable/Settable
Threshold access support Readable/Settable
Comments to this Manuals