FRU Information and Sensor Data Records
AXP 1410 Installation and Use (6806800H70D)
163
7.3.6 Power Entry Module Discrete Sensors
The following tables describe these discrete sensors available on the PEM:
z Hot Swap Sensor
z IPMB Link Sensor
z Circuit Breaker State Sensors
7.3.6.1 Hot Swap Sensor
The following table describes the discrete hot swap sensor available on the PEM.
Event message control Entire Sensor only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x3838 Upper Non-Critical, Critical and Non-
Recoverable Thresholds are Readable and
Settable
Reading Type Unsigned
Upper Non-Critical, Critical and
Non-Recoverable thresholds
0x17, 0x23, 0x2E (40.48, 61.60, 80.96) degrees C
Table 7-48 Sensor No. 12 LM73 Temp (continued)
Feature Raw Value/Description Interpreted Value
Table 7-49 Sensor No. 0, Hot Swap
Feature Raw Value/Description Interpreted Value
Sensor Name Hot Swap
Device
Sensor Type 0xF0 Hot Swap
Class 0x6F Discrete
Sensor Owner LUN 0x00
Entity ID 0x0A Power Supply
Entity Instance 0x60
Rearm Mode Auto