7.2.3.1 Hot Swap Sensor
The following table describes the discrete hot swap sensor available on the FTM.
7.2.3.2 IPMB Link Sensor
The following table describes the IPMB link sensor on the FTMs.
Table 7-25 Sensor No. 0, Hot Swap
Feature Raw Value/Description Interpreted Value
Sensor Name Hot Swap
Device
Sensor Type 0xF0 Hot Swap
Class 0x6F Discrete
Sensor Owner LUN 0x00
Entity ID 0x1E Power Supply
Entity Instance 0x60
Rearm Mode Auto
Hysteresis support
Threshold access support
Event Message Control Entire Sensor Only
Readable threshold mask,
Settable threshold mask (bytes
19, 20)
0x00FF
Reading Type According to PICMG 3.0
Table 7-26 Sensor No. 2, IPMB Physical
Feature Raw Value/Description Interpreted Value
Sensor Name IPMB Physical
Type of Measurement IPMB Link State
Class 0x6F Discrete
Event/Reading Type 0x6F Sensor-specific