Introduction
Liebert
®
Universal Monitor
4
1.7 Controller Board Overview
The Liebert Universal Monitor controller board has connectors for eight digital inputs, four analog
inputs and eight digital outputs, as shown below. The board comes complete with light emitting
diodes (LEDs) to display the status of monitored devices, a battery pack for short-term backup,
communications ports, power connections and other features necessary to monitor and protect your
operation.
Table 1 Controller board components
Item Description For more information, see:
A - Power On/Off
switch
Power switch for the controller board. When switched off, the
battery pack is disabled.
2.4: Connect Power to the Liebert
Universal Monitor
B - Battery pack
Provides battery backup during a power loss to maintain
normal operation of the panel for a minimum of 10 minutes.
The analog inputs will not be functional during a power loss
(P/N 133455P1).
2.4.3: Connecting the Battery Pack
9.9.4: Connect Battery
C - EIA422 LEDs
Indicates the connection status between the Liebert Universal
Monitor and Liebert SiteScan
®
Web.
1.9: LED Indicators
D - Audible horn Provides audible notification when an alarm occurs. N/A
E - Audible horn
jumper
Jumper to disable the audible horn (factory default is
enabled).
N/A
F - Common Alarm
connectors
The two common alarm connections are used to connect to a
secondary warning device such as a horn, light or Building
Management System (BMS). When an alarm is present, the
contacts close and the external warning device is activated/
notified. The common alarm contacts may be configured to be
reset with the Silence button/command.
4.0: Wiring and Connections -
Main Board
4.4: Connecting Common Alarm
Outputs
9.4: Setup System - Setup
Common Alarm
G - Digital output
status LEDs
Each output has an LED to indicate its status: ON/OFF
(energized/de-energized).
1.9: LED Indicators
H - Manual Override
Switch (outputs)
Placing the switch in the ON position will turn ON, or energize,
all eight outputs simultaneously. This switch removes all
automatic output control from the Liebert Universal Monitor.
9.11: Manual Output Ctrl
I - Digital output
connectors
Each of the eight output connections is a two-state point: ON/
OFF (energized/de-energized).
An example of a field digital output point is a motor starter.
4.0: Wiring and Connections -
Main Board
4.2.2: Connecting Digital Outputs
7.6: View Output Status
9.7: Setup System - Setup Output
BAR CODE
BAR CODE
LIEBERT
BATTERY
LCD
CONTRAST
VBATT
START
TB7:
24V INPUT
P23:
BATTERY
485
+
+
(TOP)
(BOTTOM)
TB10: COMMS
422
TB3:
RELAY
OUTPUTS
TB2:
CONTACT
INPUTS
ASS REV
ON
ON
PFM5
OFF
ON
PFM2
OFF
(BOTTOM)
(TOP)
4
3
2
1
8
7
6
5
(BOTTOM)
(TOP)
4
3
2
1
8
7
6
5
J11: PHONE
PIN 3-TIP
PIN 4-RING
MODEM
TB5: COMMON ALARM
(TERMINAL BLOCKS ROTATED IN VIEW)
(BOTTOM)
OM
OM
Q11
R
2
R4
0
P11
+
LS1
TOP
ENABLE
AUDIBLE
(TOP)
NO C NC NO C NC
ALL CIRCUITS:
CLASS 2
TB9: ANALOG
GROUND
AG
+ +
——
+
+
3-4 BOTTOM
1-2 TOP
ON
MODEM
4
D
CAN TX
CAN RX
DS83
DS84
1
ON
ON
TP1
GND
S2
OFF
DIP
234 5678
OUTPUT1
DS56
DS54
DS63
DS61
DS60
DS62
DS55
DS57
DS59
DS58
DS53
MOP
F PROG
574 TX
574 RX
485 RX
485 TX
OUTPUT2
OUTPUT3
OUTPUT4
OUTPUT5
OUTPUT6
OUTPUT7
OUTPUT8
CTRLLOCK
SENLOCK
CMN ALR
INPUT1
DS70
DS67
DS66
DS65
DS64
R334
INPUT2
INPUT3
INPUT4
INPUT5
INPUT6
INPUT7
INPUT8
C71
R
4
I - Digital output
connectors
L - Digital input
connectors
T - Phone
line
connector
R - EIA485
connector
S - Serial
interface
connector
(RS232/EIA574)
CC - Battery pack
connector
DD - 24VAC power
connector
EE - Transformer
Module
E - Audible horn
jumper
G - Digital output
status LEDs
K - Digital output
loss-of-power
jumper
H - Manual
Override Switch
(outputs)
X - Modem
J - Status LEDs
B - Battery
pack
A - Power
On/Off switch
AA - LCD connector
N - Analog
ground
connector
O - Analog
input
connectors
U - Power
receptacle
V - Power On/Off
switch
M - Digital input
status LEDs
BB - LCD contrast
adjustment
C - EIA422
LEDs
Y - Modem
status LEDs
P - 12VDC/24VDC
analog input
jumper
Q - Liebert
SiteScan Web
connector
(EIA422)
D - Audible
horn
Z - DIP switch 1
W - 24VAC
connector
F - Common
Alarm
connectors
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 143 144

Comments to this Manuals

No comments