Emerson Liebert APS Installation Manual

Browse online or download Installation Manual for Uninterruptible power supplies (UPSs) Emerson Liebert APS. Emerson Liebert APS Installation manual [en] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Liebert APM UPS
Modular & Scalable Digital UPS with integrated Power Distribution Unit
User & Installation Manual
Version V1.0
Revision date January 04, 2010
BOM 31012118
Emerson Network Power provides customers with technical support. Users may contact the nearest
Emerson local sales office or service center.
Copyright © 2009 by Emerson Network Power Co., Ltd.
All rights reserved. The contents in this document are subject to change without notice.
Emerson Network Power Co., Ltd.
Address: No.1 Kefa Rd., Science & Industry Park, Nanshan District 518057, Shenzhen China
Homepage: www.emersonnetworkpower.com.cn
E-mail: support@emersonnetwork.com.cn
Page view 0
1 2 3 4 5 6 ... 48 49

Summary of Contents

Page 1 - Liebert APM UPS

Liebert APM UPS Modular & Scalable Digital UPS with integrated Power Distribution Unit User & Installation Manual Version V1.0 Revision dat

Page 2 - Safety Precautions

2 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual If necessary, install a system of room extractor fans to avoid r

Page 3

Chapter 1 Installation 3 Liebert APM Modular UPS User & Installation Manual 1.4.1 UPS Composition The UPS structure is shown in Figure 1-1

Page 4

4 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual 1.4.3 Clearances The UPS has no ventilation grilles at either

Page 5 - Contents

Chapter 1 Installation 5 Liebert APM Modular UPS User & Installation Manual Power moduleA amplified viewFixing holesDIP switchReady switchA

Page 6

6 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual Earth Leakage Any residual current detector (RCD) installed upst

Page 7

Chapter 1 Installation 7 Liebert APM Modular UPS User & Installation Manual 1. Protective earth cable: Follow the most direct route possibl

Page 8

8 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual at the rear of the UPS cabinet. Tighten the output neutral bar c

Page 9 - Chapter 1 Installation

Chapter 1 Installation 9 Liebert APM Modular UPS User & Installation Manual Figure 1-5 Battery Cabinet Details Figure 1-6 Battery Conne

Page 10 - 1.4 Positioning

10 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual J8 J5J10 J7J9J6RS232 port SNMP card ports Figure 1-7 Dry con

Page 11 - 1.4.2 Moving The Cabinet

Chapter 1 Installation 11 Liebert APM Modular UPS User & Installation Manual 1.7.2 BCB Port J6 is the battery circuit breaker (BCB) port.

Page 12 - 1.4.5 Final Positioning

Safety Precautions This manual contains information concerning the installation and operation of this Liebert APM modular UPS This manual must be rea

Page 13 - 1.5 Protective Devices

12 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual 1.7.4 Output Dry Contact Port J5 is the output dry contact po

Page 14 - 1.6 Power Cables

Chapter 1 Installation 13 Liebert APM Modular UPS User & Installation Manual 1.7.6 Other Communication Interface The RS232 port provides s

Page 15 - 1.6.3 Cable Connection

14 Chapter 1 Installation Liebert APM Modular UPS User & Installation Manual 60020001100112611379711677Front viewTop view Figure 1-15 UPS

Page 16 - Warning

Chapter 1 Installation 15 Liebert APM Modular UPS User & Installation Manual NCBAAOutput terminalsA amplified view Figure 1-17 Front view

Page 17

16 Chapter 2 Operation Liebert APM Modular UPS User & Installation Manual Chapter 2 Operation This chapter introduces the basic knowledge

Page 18 - RS232 port SNMP card ports

Chapter 2 Operation 17 Liebert APM Modular UPS User & Installation Manual During normal operating conditions, the inverter output and bypass

Page 19 - 1.7.2 BCB Port

18 Chapter 2 Operation Liebert APM Modular UPS User & Installation Manual interruption is programmable but typically set to be less than 3/4

Page 20

Chapter 2 Operation 19 Liebert APM Modular UPS User & Installation Manual 2.3.2 Advanced Function——Battery Self-Test And Self-Service At p

Page 21

20 Chapter 3 Operating Procedures Liebert APM Modular UPS User & Installation Manual Chapter 3 Operating Procedures This chapter provides

Page 22 - A amplified view

Chapter 3 Operating Procedures 21 Liebert APM Modular UPS User & Installation Manual 3.2.1 Start-Up Procedures (Into Normal Mode) Procedur

Page 23

Battery voltage exceeds 400Vdc All physical battery maintenance and servicing requires the use of a tool or a key and should be carried out only by

Page 24 - Chapter 2 Operation

22 Chapter 3 Operating Procedures Liebert APM Modular UPS User & Installation Manual Battery start button Figure 3-2 Location of battery

Page 25 - 2.2.4 Bypass Mode

Chapter 3 Operating Procedures 23 Liebert APM Modular UPS User & Installation Manual 3. Open the input switch and output switch. Caution 1

Page 26 - 2.3.1 Normal Function

24 Chapter 3 Operating Procedures Liebert APM Modular UPS User & Installation Manual 3.8 Changing The Current Date And Time To change the

Page 27 - Battery EOD protection

Chapter 4 Operator Control And Display Panel 25 Liebert APM Modular UPS User & Installation Manual Chapter 4 Operator Control And Display

Page 28 - Display Panel

26 Chapter 4 Operator Control And Display Panel Liebert APM Modular UPS User & Installation Manual 4.1.1 LED Indicators The LED indicators

Page 29

Chapter 4 Operator Control And Display Panel 27 Liebert APM Modular UPS User & Installation Manual 4.1.4 LCD And Menu Keys The operator co

Page 30 - Battery start button

28 Chapter 4 Operator Control And Display Panel Liebert APM Modular UPS User & Installation Manual 4.2.2 Primary Screen After the UPS star

Page 31 - Bypass Mode

Chapter 4 Operator Control And Display Panel 29 Liebert APM Modular UPS User & Installation Manual 4.2.3 Default Screen During UPS operati

Page 32

30 Chapter 4 Operator Control And Display Panel Liebert APM Modular UPS User & Installation Manual Menu Item Explanation Power factor Powe

Page 33 - 12:30:36

Chapter 4 Operator Control And Display Panel 31 Liebert APM Modular UPS User & Installation Manual Menu Item Explanation Battery maintenanc

Page 35 - 4.2.1 Start Screen

32 Chapter 4 Operator Control And Display Panel Liebert APM Modular UPS User & Installation Manual 4.5 Alarm List The following table prov

Page 36 - 4.2.2 Primary Screen

Chapter 4 Operator Control And Display Panel 33 Liebert APM Modular UPS User & Installation Manual Alarm Explanation Inverter asynchronous T

Page 37 - 4.2.3 Default Screen

34 Chapter 4 Operator Control And Display Panel Liebert APM Modular UPS User & Installation Manual Alarm Explanation Alarm silence SILENCE

Page 38

Chapter 5 Service 35 Liebert APM Modular UPS User & Installation Manual Chapter 5 Service This chapter introduces the UPS service, includi

Page 39 - Keypad window

36 Chapter 5 Service Liebert APM Modular UPS User & Installation Manual 6. After servicing the module, push the module (at least 10s after a

Page 40 - 4.5 Alarm List

Chapter 6 Specifications 37 Liebert APM Modular UPS User & Installation Manual Chapter 6 Specifications The chapter provides the UPS speci

Page 41

38 Chapter 6 Specifications Liebert APM Modular UPS User & Installation Manual 6.4 Electrical Characteristics (Input Rectifier) Table 6-4

Page 42

Chapter 6 Specifications 39 Liebert APM Modular UPS User & Installation Manual 6.6 Electrical Characteristics (Inverter Output) Table 6-6

Page 43 - Chapter 5 Service

40 Chapter 6 Specifications Liebert APM Modular UPS User & Installation Manual 6.7 Electrical Characteristics (Bypass Mains Input) Table 6

Page 44 - Fixing bar

Appendix 1 BCB Model Selection And Connection 41 Liebert APM Modular UPS User & Installation Manual Appendix 1 BCB Model Selection And Conn

Page 45 - Chapter 6 Specifications

Contents Chapter 1 Installation ...

Page 46 - Table 6-5 Battery

2.2.2 Battery Mode ...

Page 47

Chapter 5 Service ...

Page 49

Chapter 1 Installation 1 Liebert APM Modular UPS User & Installation Manual Chapter 1 Installation This chapter introduces the installatio

Comments to this Manuals