Emerson VSG & VSSG Troubleshooting Guide Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
VSG/VSSG • Compact Logix PLC Manual •Vilter/Emerson • 35391CL
Operational Flow Charts
Volume and
Capacity slides are
less than 5 %.
Requirements to Start Compressor
Oil Separator Temp
> Oil Sep Start
Trip
Setpt.
Filter Diff Press <
Start
Filter Diff
Trip Setpt
Oil Pump On: Prelub Oil Press is > Prelub Oil
Press Reset Setpt for “Min Compressor Prelub
Timer” setting (Default 7 Seconds)
Start Compressor
Critical Compressor Run Logic @ Compressor Start
Is
Run Oil Press >
Run Oil Press
Reset
setpt?
(Default 40 PSI)
Run Oil Press Failure
“Filter Diff Press Safety
Changeover” timer expires
(60 sec after start).
Is
Filter Diff < Hi Filter
Diff Press Run Trip
setpt?
Oil Separator Temp
Safety Changeover
Timer expires. (5 min
after start)
Is
Oil Sep Temp > Lo
Oil Sep Run Reset
setpt:?
Run
Run Filter Diff Press Failure Lo Run Oil Sep Temp Failure
No
Yes
No
Yes Yes
No
Yes
Compressor Amperage Load Limiting
High Disch Pressure Load Limit
Is
Motor Amps >
FLA (ON
)
Setpt?
Is
Motor Amps >
Max (OFF
)
Setpt?
Normal Loading &
Unloading
Capacity Decrease
until Amps < FLA x
1.0625
Normal Loading &
Unloading
Capacity Decrease until
DischPress < ON Setpt x
1.0625
Is
Disch Press >
Cutin (ON
)
Setpt?
Is
Disch Press >
Cutout (OFF
)
Setpt?
No
Yes
Yes
No
No
Yes
Yes
No
Capacity INC Disabled
Capacity INC Disabled
Start
Compressor
Prelube 5
Seconds
Satified Oil
Pressure
Compressor
Start Mode
Is Run Oil Press >
Run Oil Press setpt?
Yes
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 71 72