VSG/VSSG • Compact Logix PLC Manual •Vilter/Emerson • 35391CL
Compressor Setpoints and Alarms
· Prelube Oil Pressure – This is the low Prelube
Oil Pressure safety. The Trip will be active if the
compressor is in Pre-lube and the Oil Pressure
drops below the set-point value.
· Low Oil Pressure – This is the Low Oil Pressure
Safety. The Alarm and Trip will occur if the Oil
Pressure drops below the set-point(s) value.
· High Filter Differential Pressure – Start – This is
the High Filter Differential Pressure (at compres-
sor Start) Safety. The Alarm and Trip will occur
if the Oil Differential Pressure (Filter Inlet Pres-
sure – Manifold Pressure) at Compressor Start
is above the set-point(s).
· High Filter Differential Pressure – Run – This is
the High Filter Differential Pressure (while the
compressor is running) Safety. The Alarm and
Trip will occur if the Oil Differential Pressure (Fil-
ter Inlet Pressure – Manifold Pressure) while the
Compressor is running above the set-point(s).
· High Motor Amps – This is the High Motor Amps
Safety. The Alarm and Trip will occur if the Motor
Amps exceed the set-point(s).
· Motor Winding Temperature - This is the High
Winding Temperature Safety. The Alarm and
Trip will occur if the Motor Winding Tempera-
ture is above the set-point(s). These set-points
are only active when the compressor has been
selected to have Motor Winding Temperature
RTDs.
· Motor Bearing Temperature - This is the High
Bearing Temperature Safety. The Alarm and Trip
will occur if the Motor Bearing Temperature is
above the set-point(s). These set-points are only
active when the compressor has been selected
to have Motor Winding Temperature RTDs.