Emerson ZB Copeland Scroll Service Manual Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
19
50 Hz
-15
1810
1540
750
1060
1900
1670
1020
1280
2580
2270
1180
1450
2690
2280
1360
1770
3500
3050
1630
2050
4300
3800
1900
2350
5200
4500
2280
2900
-5
2950
2570
2110
720
1020
1390
3250
2900
2450
1010
1290
1630
4200
3800
3200
1190
1480
1830
4550
4000
3350
1330
1710
2160
5750
5100
4300
1630
2040
2550
7050
6350
5400
1950
2400
2980
8450
7500
6250
2290
2880
3640
-10
2360
1980
1640
730
1040
1410
2560
2190
1880
1020
1290
1630
3400
2900
2510
1190
1470
1810
3600
3000
2550
1340
1730
2210
4600
3950
3350
1630
2050
2570
5650
4900
4250
1930
2380
2960
6800
5750
4900
2280
2880
3660
0
3600
3150
2650
710
1000
1370
4100
3650
3150
1000
1280
1610
5150
4650
4000
1200
1490
1840
5600
5000
4250
1320
1690
2130
7050
6300
5400
1630
2030
2540
8650
7800
6750
1960
2420
2990
10400
9250
7850
2300
2890
3630
5
4350
3850
3350
710
980
1340
5000
4500
3950
990
1270
1600
6300
5650
5000
1210
1500
1850
6800
6100
5400
1320
1690
2120
8550
7700
6750
1630
2020
2520
10550
9500
8400
1980
2450
3010
12650
11300
9850
2320
2900
3630
10
5300
4700
4050
740
970
1310
6050
5400
4800
980
1260
1580
7550
6800
6000
1230
1510
1870
8150
7350
6550
1310
1680
2110
10250
9250
8150
1640
2020
2520
12700
11450
10150
2010
2480
3050
15200
13650
11950
2350
2920
3630
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
35
45
55
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
ZB15KQE
ZB19KQE
ZB21KQE
ZB26KQE
ZB30KQE
ZB38KQE
ZB45KQE
+ Capacity based on 20
o
C suction temp,no sub-cooling.
+ Max suction superheat is 11K.
ZB Series
Con. Temp.
o
C
Model
Evaporating Temperature
o
C
Performance Data
Q=Capacity (Watts) P=Power input (Watts)
Page view 20