26
ZB Series
60 Hz
-23
3150
2710
1460
1840
3900
3400
1830
2300
4650
4050
2190
2750
5450
4750
2560
3210
6100
5200
3060
3720
7600
6400
3660
4450
-20
3550
3100
2555
1470
1840
2310
4450
3850
3200
1840
2300
2890
5300
4600
3800
2200
2760
3460
6200
5350
4450
2570
3220
4040
6950
5950
4850
3080
3740
4550
8700
7350
6000
3680
4480
5450
-15
4350
3750
3150
1480
1850
2320
5400
4700
3900
1850
2310
2890
6450
5600
4700
2220
2780
3470
7550
6550
5450
2590
3240
4050
8600
7400
6100
3100
3760
4580
10750
9200
7500
3720
4520
5500
-10
5250
4550
3800
1490
1860
2320
6550
5650
4750
1860
2320
2900
7800
6800
5650
2230
2790
3480
9150
7950
6650
2600
3250
4060
10450
9050
7500
3130
3790
4600
13100
11250
9250
3770
4560
5550
-5
6250
5450
4550
1490
1860
2320
7850
6800
5700
1860
2330
2900
9350
8150
6800
2230
2790
3480
10950
9500
7950
2610
3260
4070
12550
10900
9100
3170
3820
4630
15700
13600
11250
3840
4610
5600
0
7450
6450
5450
1490
1860
2320
9300
8100
6800
1860
2320
2900
11150
9650
8100
2230
2790
3480
13000
11300
9500
2600
3260
4060
15000
13000
10850
3220
3850
4650
18600
16200
13550
3950
4690
5650
5
8800
7650
6400
1480
1850
2320
10950
9550
8000
1850
2320
2890
13100
11400
9600
2220
2780
3470
15300
13300
11200
2590
3240
4050
17700
15400
12900
3280
3890
4690
21700
19100
16100
4100
4790
5750
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
30
40
50
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
ZB15KQ
ZB19KQ
ZB21KQ
ZB26KQ
ZB30KQ
ZB38KQ
Con. Temp.
o
C
Model
Evaporating Temperature
o
C
Performance Data
Q=Capacity (Watts) P=Power input (Watts) 1-Phase
+ Capacity based on 20
o
C suction temp,no sub-cooling.
Page view 27