Emerson CP400 Instruction Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
CP400 Series
3
Available Congurations
See Table 1
Body Sizes, End Connections Styles and
Pressure Rating
(1)
See Table 4
Maximum Operating Inlet Pressure
(1)
See Table 2
Maximum Outlet Pressures
(1)
See Table 3
Outlet Pressure Ranges
See Table 5
Orice Sizes
See Table 2
Flow and IEC Sizing Coefcients
See Table 2
Temperature Capabilities
(1)(2)
-20 to 150°F / -29 to 66°C
Control Line Connection
3/4 NPT
Pressure Registration
Types CP400IT, CP400IN, CP403IT, CP403IN,
CP404IN and CP404IT: Internal
Types CP400ET, CP400EN, CP403ET, CP403EN,
CP404EN and CP404ET: External
Specications
Optional Internal Token Relief Performance
(Located in Type 67CPR Pressure Loading Regulator)
Token relief is a low capacity relief intended to
relieve overpressure occurrences due to minor
seat leakage or thermal expansion only; other
overpressure protection must be provided if inlet
pressure can exceed the maximum pressure rating
of downstream equipment or maximum outlet
pressure rating of the regulator.
Token Relief Start-to-Discharge
See Table 6
Factory Setpoint Inlet Pressures for Various
Orice Sizes
3/16-inch / 4.8 mm: 60 psig / 4.1 bar
1/4-inch / 6.4 mm: 40 psig / 2.8 bar
3/8-inch / 9.5 mm: 25 psig / 1.7 bar
1/2-inch / 13 mm: 25 psig / 1.7 bar
5/8-inch / 16 mm: 15 psig / 1.0 bar
3/4-inch / 19 mm: 10 psig / 0.69 bar
Option
1/4 NPT Type P593-1 Aluminum Body
Cellulose Filter
Approximate Weights
With threaded body
Type CP400: 11 pounds / 5.0 kg
Type CP403: 20.5 pounds / 9.3 kg
Type CP404: 13.2 pounds / 6.0 kg
Add 8.6 pounds / 3.9 kg to weights listed
with anged body
1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
2. Product has passed Regulator Technologies testing for lockup, relief start-to-discharge and reseal down to -40 degrees.
ORIFICE SIZE
MAXIMUM OPERATING
INLET PRESSURE
FLOW COEFFICIENTS
(WIDE OPEN)
C
1
IEC SIZING COEFFICIENTS
Inch mm psig bar C
g
C
v
X
T
F
D
F
L
3/16 4.8 125 8.6 27 0.97 27.7 0.50 0.91
0.89
1/4 6.4 125 8.6 50 1.77 28.2 0.50 0.92
3/8 9.5 80 5.5 113 3.72 30.4 0.58 0.89
1/2 13 60 4.1 182 5.61 32.4 0.66 0.82
5/8 16 50 3.4 284 7.26 39.1 0.97 0.74
3/4 19 40 2.8 356 9.83 36.2 0.83 0.72
Table 2. Inlet Pressure Ratings and Flow and Sizing Coefcients
The Specications section lists the specications for the regulators. The following information is stamped on the
regulator at the factory: Type, date of manufacture, spring range, orice size, maximum inlet pressure, maximum
operating outlet pressure and outlet pressure which may damage parts.