CP400 Series
18
GE27401
Figure 13. CP400 Series Slam shut and Integral Monitor Modules
GE27401_C
APPLY LUBRICANT (L)
(1)
:
L1 = ANTI-SEIZE LUBRICANT
L2 = SILICON GREASE
1. Lubricants must be selected such that they meet the temperature requirements.
TRUE-MONITOR™ ASSEMBLY
26
L1
27
70
L2
27
L2
25
101
L1
TORQUE:
35 TO 45 FOOT-POUNDS /
47 TO 61 N•m
TORQUE:
35 TO 45 FOOT-POUNDS /
47 TO 61 N•m
26
L1
27
70
L2
27
L2
25
101
L1
TORQUE:
35 TO 45 FOOT-POUNDS /
47 TO 61 N•m
SLAM-SHUT ASSEMBLY
TORQUE:
35 TO 45 FOOT-POUNDS /
47 TO 61 N•m