6 – 7
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG
Problem Solution
High Amp Draw Check Main Motor Amps scaling and PLC.
Vibration
Check that unit is leveled and secured to mounting pad or oor.
Check supported pipes (i.e. suction and discharge pipe) and make sure they
are adequately supported.
Check for loose bolts and nuts.
Check condition of compressor and motor (i.e. alignments)
Excessive Motor Backspin
If there is more than normal motor backspin at shutdown, check suction
check valve for proper operation.
Table 6-3. Troubleshooting Guide - General Problems & Solutions (3 of 3)
Section 6 • Troubleshooting
Page view 94