Emerson VSG & VSSG Installation Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 106
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
3 – 11
VSG/VSSG • Installation, Operation and Maintenance Manual •Vilter/Emerson • 35391SSG
Figure 3-9. Maximum Allowable Flange Loads
DISCHARGE
LINE
5 PIPE
DIAMETERS
CUSTOMER
SUPPORT
3-4 PIPE
DIAMETERS
SUCTION
LINE
X
Z
Z
Y
X
Y
CUSTOMER
SUPPORT
HANGER
CHECK
VALVE
CUSTOMER SUPPORTS
WHEN CHECK VALVE
IS MOUNTED HERE
5 PIPE
DIAMETERS
5 PIPE
DIAMETERS
Nozzle Dia. (in.) Fz (lbf) Fy (lbf) Fx (ft-lbf) Mzz (ft-lbf) Myy (ft-lbf) Mxx (ft-lbf)
4 400 400 400 300 300 300
6
600 600 600 500 500 500
8 900 900 900 1000 1000 1000
10 1200 1200 1200 1200 1200 1200
12 1500 1500 1500 1500 1500 1500
14 2000 2000 2000 2000 2000 2000
Section 3 • Installation
Table 3-2. Maximum Allowable Flange Loads
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 105 106