Emerson 1805 Series Relief Valves Datasheet

Browse online or download Datasheet for Unknown Emerson 1805 Series Relief Valves. Emerson 1805 Series Relief Valves Data Sheet User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Bulletin 71.4:1805
October 2011
D100160X012
www.sherregulators.com
Type 1805-2
P1026
1805 Series Relief Valves
Introduction
The 1805 Series relief valves are designed for use
in farm tap applications where a safety relief valve is
needed between the rst and second stage regulators.
The 1805 Series is suitable for natural gas, air,
propane, or any operating medium that is not corrosive
to the internal parts. Relief pressures range from 5
to 125 psig / 0,34 to 8,6 bar. Maximum pressure,
including buildup, is 150 psig / 10,3 bar.
Features
Tight Shutoff—Provided by the Nitrile (NBR)
O-ring and O-ring seat.
Easy Maintenance—The union nut allows quick
removal of the cage assembly for trim inspection.
The valve can be back in operation in a matter
of minutes.
Simple Adjustment—A single adjusting screw is
used to meet individual application requirements.
Complete Venting—A closing cap is available if
all venting must be piped away.
Sour Gas Service Capability—Optional materials
are available for applications handling sour gases.
These constructions comply with the
recommendations of the NACE International
Standards MR0175 and MR0103.
Figure 1. Typical 1805 Relief Valves
Type 1805-4
1805G
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - 1805 Series Relief Valves

Bulletin 71.4:1805October 2011D100160X012www.sherregulators.comType 1805-2P10261805 Series Relief ValvesIntroductionThe 1805 Series relief valves are

Page 2 - Bulletin 71.4:1805

Bulletin 71.4:18052SpecicationsAvailable Constructions See Table 2Body Style Globe bodyBody Sizes and End Connection Style 3/4, 1, 1-1/2, or 2 NPT

Page 3 - Type XXXX

Bulletin 71.4:18053Type XXXXMXXXXINLET PRESSUREOUTLET PRESSUREATMOSPHERIC PRESSUREMonth YearType XXXXTANK PRESSUREVACUUM PRESSUREPRE-EXPANSION PRESSUR

Page 4

Bulletin 71.4:180541. SETPOINT IS TO BE INTERPRETED AS BUBBLE POINT*MAXIMUM PRESSURE INCLUDING BUILDUP - 150 psig / 10,3 bar AT 150°F / 66°C.3/4 AND 1

Page 5

Bulletin 71.4:18055InstallationThe 1805 Series relief valves may be installed in any position. However, the outlet connection and vents must be prote

Page 6

Bulletin 71.4:18056Figure 5. 1805 Series Dimensional DrawingsTYPE 1805-4 OR 1805-5 WITHOUT CLOSING CAPTYPE 1805-2, 1805-3, OR 1805-7 WITH CLOSING CAP

Page 7

Bulletin 71.4:18057Regulators Quick Order Guide* * *Readily Available for Shipment* *Allow Additional Time for Shipment*Special Order, Constructed fro

Page 8

Bulletin 71.4:1805©Emerson Process Management Regulator Technologies, Inc., 2011; All Rights ReservedThe Emerson logo is a trademark and service mark

Comments to this Manuals

No comments