Type T205B
D103750X012
Instruction Manual
April 2014
www.fisherregulators.com
Type T205B Balanced Tank Blanketing Regulator
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
tank blanketing regulators must
be installed, operated and maintained
in accordance with federal, state and
local codes, rules and regulations
and Emerson Process Management
Regulator Technologies, Inc. (Regulator
Technologies) instructions.
If the regulator discharges process  uid or
a leak develops in the system, service to
the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Call a quali ed service person to service
the unit. Installation, operation and
maintenance procedures performed by
unquali ed person may result in improper
adjustment and unsafe operation. Either
condition may result in equipment damage
or personal injury. Only a quali ed person
must install or service the Type T205B tank
blanketing regulator.
Introduction
Scope of the Manual
This Instruction Manual provides instruction
for installation, startup, maintenance and parts
ordering information for Type T205B tank
blanketing regulator.
Product Description
Type T205B balanced tank blanketing regulator
(Figure 1) is a direct-operated regulator with fully
balanced plug design to reduce inlet pressure sensitivity
and with large diaphragm to accurately control tank
pressure at low pressure settings on tank blanketing
systems. The regulator prevents a stored liquid
from vaporizing into the atmosphere, reduces liquid
combustibility and prevents oxidation or contamination
of the liquid by reducing its exposure to air. Type T205B
maintains a slightly positive pressure and thereby
reduces the possibility of tank wall collapse during pump
out operation.
Contents
Introduction .................................................................. 1
Specifications .............................................................. 2
Principle of Operation .................................................. 3
Installation ................................................................... 4
Startup ......................................................................... 6
Adjustment...................................................................6
Shutdown.....................................................................7
Maintenance ................................................................ 7
Parts List.................................................................... 11
Figure 1. Type T205B Tank Blanketing Regulator
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Type T205B

Type T205BD103750X012Instruction ManualApril 2014www.fisherregulators.comType T205B Balanced Tank Blanketing Regulator!WARNINGFailure to follow these

Page 2

Type T205B10Figure 6. Type T205B Regulator Assembly (continued) APPLY LUBRICANT (L)(2) L2 = ANTI-SEIZE COMPOUND1. For 1.2 to 2.5 psig / 83 to 1

Page 3

Type T205B11* Recommended spare part1. Use for external square head adjusting screw assembly option for 1.2 to 2.5 psig / 83 to 172 mbar, 2.5 to 4.5

Page 4

Type T205B©Emerson Process Management Regulator Technologies, Inc., 2013, 2014; All Rights ReservedThe Emerson logo is a trademark and service mark of

Page 5

Type T205B2SpecicationsThis section lists the specications of the Type T205B Tank Blanketing Regulator. Factory specication, such as maximum temper

Page 6

Type T205B3When pressure in the tank increases, the actuator diaphragm is pushed. Through the action of the pusher post assembly, lever and valve stem

Page 7

Type T205B4Figure 3. Type T205B Actuator Casing Drainage Installation!WARNINGPersonal injury, property damage, equipment damage or leakage due to esca

Page 8

Type T205B5Figure 4. Balanced Trim Assembly!WARNINGA regulator may vent some gas to the atmosphere. In hazardous or  ammable gas service, vented gas

Page 9

Type T205B6Startup1. Open shutoff valves between the tank blanketing regulator and the tank (both sensing and outlet).2. Slowly open the supply line

Page 10

Type T205B7gauge to monitor the tank blanketing gas pressure when making adjustments.3. After making the adjustment, tighten the locknut (key 20).Shu

Page 11

Type T205B82. Turn the adjusting screw (key 35) counterclockwise to remove all the compression from the control spring (key 6).3. If the only mainte

Page 12

Type T205B9Figure 6. Type T205B Regulator Assembly APPLY LUBRICANT (L)(1): L1 = MULTI-PURPOSE PTFE LUBRICANT L2 = ANTI-SEIZE COMPOUND1. Lubr