20 Mentor MP Short Form Guide
www.leroy-somer.com Issue : c
Place finger-guard on a flat solid surface and hit relevant break-outs with hammer as
shown (1). Continue until all required break-outs are removed (2). Remove any flash /
sharp edges once the break-outs are removed.
3.3 Mounting method
The Mentor MP can only be surface mounted.
Figure 3-3 Overall size 1A dimensions
1. The two outer holes must be used for mounting the Mentor MP.
.
293mm (11.54in)
250mm (9.84in)
444mm
(17.48in)
222mm
(8.74in)
95mm
(3.74in)
222mm (8.74in)
170mm (6.69in)
6.5mm (0.26in)
250mm (9.84in)
40mm
(1.58in)
22mm
(0.87in)
380mm
(14.96in)
4 holes to
suit M6
1
1
1
1
MA1
MA2
With the SMARTCARD installed to the drive, the depth measurement increases by
7.6mm (0.30 in).
Fans are only installed to the MP75A4(R) and MP75A5(R)