Table 2-4 690V current ratings
* For this rating at 690V, 150% overload time is 20s at 40°C and 30s at 35°C.
Maximum continuous input current
The values of maximum continuous input current are given to aid the selection of cables
and fuses. These values are stated for worst-case condition.
2.3 Model number
The way in which the model numbers for the Mentor MP range are formed is described
in Figure 2-1.
Figure 2-1 Model number
Model
AC input
current
DC output Current
Typical motor
power (With Vdc
= 760V)
Continuous Continuous
150%
Overload
AAAkWhp
MP350A6(R) 313 350 525 240 320
MP470A6(R) 420 470* 705 320 425
MP700A6(R) 626 700 1050 480 640
MP825A6(R) 738 825* 1237.5 650 850
MP1200A6(R) 1073 1200 1800 850 1150
MP1850A6(R) 1655 1850 2775 1300 1750
For current ratings above 1850A then parallel connection of the drives is required.
However, this function is not implemented on firmware versions V01.05.01 and earlier.
NOTE
Mentor product line
MP
:
Continuous armature current rating (A)
Voltage rating
4 = 480V 24V to 480V -20% +10%
5 = 575V 500V to 575V -10% +10%
6 = 690V 500V to 690V -10% +10%
Mentor Platform
MP 2 0 01 4 R
R
Blank
-
4 quadrant operation
- 2 quadrant operation
A