Table 7-2 Quick start commissioning / start up from defaults for Mentor MP mode
Action Detail
Before power up
Ensure:
Motor field is connected.
The MP port on the FXMP25 is connected to the external
field controller port on the Mentor MP using a shielded
straight through RJ45 to RJ45 lead, maximum length 100 m.
Mentor MP software must be V01.05.01 or later.
Power up the field
controller
Ensure:
The field controller displays:
If the field controller trips, see Chapter 9 Diagnostics on
page 60.
Select Mentor MP
mode
To select MP mode
•Set Pr 78 (Field mode) = MP (1)
Press the mode button to enter parameter view mode
Press and hold the mode button for at least 2 seconds to
carry out a reset.
Setting up the field
controller
The Mentor MP has taken control of the FXMP25. Setting up
should now be carried out using the Mentor MP. Please refer to
the running a motor section in Mentor MP Short Form Guide.
Setting in MP Set Pr 5.78 to EXTERNAL