32 FXMP25 User Guide
www.controltechniques.com Issue Number: 3
The average measured DC input voltage seen across the field controller A1 and A2
terminals.
This parameter displays the level of the analog signal present at the flux reference input,
this is a unipolar voltage input where the input range is 0 V to +10 V.
An offset can be added to flux reference input with a range from -100.0 % to 100.0 %. If
the sum of the input and the offset is outside the range 0 to 100 % the result will be
clamped at 0 or 100 %.
The flux reference input is connected to the field economy parameter when the flux
input is selected. The maximum value of the field economy is 100 % and so the default
for the scaling parameter is 1 so that the demand is 100 % for 10 V input.
The maximum value of Pr 02 is 860 which without any scaling will be converted to 10 V.
This parameter should be adjusted by the user for other full scale voltages.
02 Armature voltage
Coding
Bit FI Txt VM DP ND US RW BU PS
111
Range 0 to 860 V
Update rate Background write
03 Flux reference
Coding
Bit FI Txt VM DP ND US RW BU PS
111 1
Range 0.0 to 100.0 %
Update rate Background
04 Flux reference input offset
Coding
Bit FI Txt VM DP ND US RW BU PS
111
Range ±100 %
Default 0.0
Update rate Background read
05 Flux reference scaling
Coding
Bit FI Txt VM DP ND US RW BU PS
3111
Range 0.000 to 4.000
Default 1.000
Update rate Background
06 Armature voltage output scaling
Coding
Bit FI Txt VM DP ND US RW BU PS
3111
Range 0.000 to 4.000
Default 1.000
Update rate Background
Page view 31