Emerson DLC3010 Quick Start Guide

Browse online or download Quick Start Guide for Measuring, testing & control Emerson DLC3010. Emerson DLC3010 Quick Start Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.Fisher.com
Fisherr FIELDVUE
DLC3010 Digital Level
Controller
Contents
Installation 3.....................
Mounting 9.......................
Electrical Connections 13...........
Initial Setup 21....................
Calibration 27.....................
Schematics 32....................
Specifications 34..................
Note
This guide describes how to install, setup, and calibrate DLC3010 digital level controllers using a 475 Field Communicator.
Additional information for installing, operating, and maintaining the DLC3010 digital level controllers can be found in the related
documents listed on page 42. For information on using the Field Communicator, see the Product Manual
for the Field
Communicator, available from Emerson Performance Technologies.
Quick Start Guide
D103214X012
DLC3010 Digital Level Controller
September 2014
This quick start guide applies to:
Device Type 3010
Device Revision 1
Hardware Revision 1
Firmware Revision 8
DD Revision 3
W7977-1
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - Controller

www.Fisher.comFisherr FIELDVUE™ DLC3010 Digital LevelControllerContentsInstallation 3...Mounting 9...Electrical

Page 2 - Mounting

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201410DLC3010 OrientationMount the digital level controller with the torque tube

Page 3 - Installation

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201411Figure 5. Typical Mounting Positions for FIELDVUE DLC3010 Digital Level Co

Page 4

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201412Mounting the Digital Level Controller for Extreme TemperatureApplicationsR

Page 5 - Lever Lock

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014131. For mounting a digital level controller on a 249 sensor, secure the sh

Page 6 - WARNING

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201414Figure 9. Connecting a Field Communicator to the Digital Level Controller

Page 7

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201415Field Wiring WARNINGTo avoid personal injury or property damage caused

Page 8

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201416Grounding WARNINGPersonal injury or property damage can result from fir

Page 9

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201417Communication Connections WARNINGPersonal injury or property damage cause

Page 10 - DLC3010 Orientation

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201418the instrument drives its output to either below 3.70 mA or above 22.5 mA,

Page 11 - Quick Start Guide

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201419Loop Test (optional)Field Communicator Service Tools > Maintenance >

Page 12 - Applications

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20142nInstallation Check ListInstrument correctly configured and mounted on the

Page 13 - Electrical Connections

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201420nConfiguration and Calibration Check ListInitial setup complete. Perform t

Page 14

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201421Configuration and Calibration Initial SetupIf a DLC3010 digital level cont

Page 15 - Field Wiring

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201422D Instrument mounting (right or left of displacer)D Measurement Applicatio

Page 16 - Grounding

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201423Figure 12. Example Sensor NameplateDISPLACERPRESSURE RATING1500 PSI103 CU‐

Page 17 - Alarm Jumper

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201424HORIZONTAL CLOF TORQUE TUBEVERTICAL CL OF DISPLACERMOMENTARM LENGTHVESSELF

Page 18 - Changing Jumper Position

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014258. The default values of the alarm variables will be set as follows:Direc

Page 19 - Loop Test (optional)

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201426Coupling If the digital level controller is not already coupled to the se

Page 20 - September 2014

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201427CalibrationGuided CalibrationField Communicator Configure > Calibration

Page 21 - Initial Setup

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201428until sufficient buoyancy has developed to allow the linkage to move. In t

Page 22 - Guided Setup

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201429The calibration process flows as follows:D Change the PV mode to Level.D S

Page 23

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20143Installation WARNINGTo avoid personal injury, always wear protective glov

Page 24

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201430Density Applications - with Standard Displacer and Torque TubeNoteWhen you

Page 25

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014311. Determine all the information you can about the 249 hardware: 249 type

Page 26 - Coupling

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201432SchematicsThis section includes loop schematics required for wiring of int

Page 27 - Calibration

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201433Figure 15. FM Loop Schematic28B5745‐C1. THE INSTALLATION MUST BE IN ACCOR

Page 28

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201434SpecificationsSpecifications for DLC3010 digital level controllers are sho

Page 29

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201435Table 6. DLC3010 Digital Level Controller SpecificationsAvailable Configur

Page 30

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201436Table 6. DLC3010 Digital Level Controller Specifications (continued)Electr

Page 31

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201437Table 6. DLC3010 Digital Level Controller Specifications (continued)Minimu

Page 32 - Schematics

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201438Table 7. EMC Summary Results—ImmunityPort Phenomenon Basic Standard Test L

Page 33

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201439Figure 16. Theoretical Reversible Temperature Effect on Common Torque Tube

Page 34 - Specifications

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20144Figure 1. Installation FlowchartSTART HEREFactory mountedon 249 sensor?Use

Page 35 - J reverse action—increasing

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201440Table 8. 249 Sensor SpecificationsInput SignalLiquid Level or Liquid‐to‐Li

Page 36

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201441Table 11. Caged Displacer Sensors(1)TORQUE TUBEORIENTATIONSENSORSTANDARD C

Page 37 - J Mountings for Masoneilant

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201442Figure 17. Style Number of Equalizing ConnectionsSTYLE 1TOP AND BOTTOM CON

Page 38

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201443D Bolt Torque Information - Supplement to 249 Sensor Instruction Manuals (

Page 39

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201444Emerson Process Management Marshalltown, Iowa 50158 USASorocaba, 18087 Bra

Page 40 - J Reflex gauges for

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20145Configuration: On the Bench or in the LoopConfigure the digital level contr

Page 41

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20146CAUTIONWhen shipping an instrument mounted on a sensor, if the lever assemb

Page 42 - Related Documents

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20147Table 1. Hazardous Area Classifications—CSA (Canada)Certification Body Cert

Page 43 - Educational Services

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20148Type nThis equipment shall be used with a cable entry ensuring an IP66 mini

Page 44

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20149Mounting Mounting the 249 SensorThe 249 sensor is mounted using one of two