Model 6081-P
Wireless pH/ORP Transmitter
Instruction Manual
PN 51-6081P/rev.A
November 2008
Page view 0
1 2 3 4 5 6 ... 61 62

Summary of Contents

Page 1 - Model 6081-P

Model 6081-PWireless pH/ORP TransmitterInstruction ManualPN 51-6081P/rev.ANovember 2008

Page 2 - ESSENTIAL INSTRUCTIONS

MODEL 6081-P pH/ORP TABLE OF CONTENTivThis page left blank intentionally

Page 3 - About This Document

MODEL 6081-P pH/ORP SECTION 1.0DESCRIPTION AND SPECIFICATIONSSECTION 1.0DESCRIPTION AND SPECIFICATIONS1• HIGH ACCURACY AND RELIABILITY for monitoringa

Page 4 - QUICK START GUIDE

MODEL 6081-P pH/ORP SECTION 1.0DESCRIPTION AND SPECIFICATIONS21.3 SPECIFICATIONS - WIRELESSOutput: WirelessHART V7Transmit Rate: User selectable, 1/se

Page 5

3MODEL 6081-P pH/ORP SECTION 1.0DESCRIPTION AND SPECIFICATIONS1.5 Product CertificationsTelecommunication ComplianceAll wireless devices require certi

Page 6

MODEL 6081-P pH/ORP SECTION 1.0DESCRIPTION AND SPECIFICATIONS1.7 ASSET MANAGEMENT SOLUTIONSAsset Management Solutions (AMS) is software that helps pla

Page 7 - WIRELESS TRANSMITTER

MODEL 6081-P pH/ORP SECTION 2.0INSTALLATIONSECTION 2.0INSTALLATION2.1 Considerations2.2 Unpacking and Inspection2.3 Pre-Installation Set Up2.4 Mechani

Page 8 - TABLE OF CONTENTS CONT’D

62.3 PRE-INSTALLATION SETUP2.3.1 Temperature ElementThe Model 6081-P pH/ORP transmitter is compatible with sensors having Pt 100 and Pt 1000. Sensors

Page 9 - LIST OF FIGURES

7WARNINGFailure to follow these installation guidelines could result in death or serious injury.• Make sure only qualified personnel perform the insta

Page 10

8MODEL 6081-P pH/ORP SECTION 2.0INSTALLATION2.4.2 Mounting on a Flat Surface.Figure 2-1. Wall Mounting Installation Model 6081. Use Pipe/Wall Mountin

Page 11 - SECTION 1.0

9MODEL 6081-P pH/ORP SECTION 2.0INSTALLATION2.4.3 Pipe Mounting.The pipe mounting kit (PN 23820-00/01) accommodates 1-1/2 to 2 in. pipe.Figure 2-2. Pi

Page 12 - 1.4 FUNCTIONAL SPECIFICATIONS

ESSENTIAL INSTRUCTIONSREAD THIS PAGE BEFORE PROCEEDING!Rosemount Analytical designs, manufactures, and tests its products to meet many national and i

Page 13 - 1.6 HART COMMUNICATIONS

102.6 POWER MODULE INSTALLATION The section describes the procedure for installation of the power module (part number 00753-9220-0001). Thepower modu

Page 14

4. With gentle pressure, insert the keyed connector on the power module into the receptacle (labeled Power Module Connection on the drawing). The p

Page 15 - INSTALLATION

12This page left blank intentionallyMODEL 6081-P pH/ORP SECTION 2.0INSTALLATION

Page 16 - 2.3 PRE-INSTALLATION SETUP

MODEL 6081-P pH/ORP SECTION 3.0 WIRINGSECTION 3.0SENSOR WIRING3.1 GENERAL INFORMATIONpH and ORP sensors without preamps manufactured by Rosemount Anal

Page 17

14MODEL 6081-P pH/ORP SECTION 3.0 WIRINGThis page left blank intentionally

Page 18

15MODEL 6081-P pH/ORP SECTION 4.0INTRINSICALLY SAFE & EXPLOSION PROOF15SECTION 4.0INTRINSICALLY SAFE INSTALLATIONThis page left blank intentionall

Page 19 - 2.4.3 Pipe Mounting

16MODEL 6081-P pH/ORP SECTION 4.0INTRINSICALLY SAFE & EXPLOSION PROOFThis page left blank intentionally

Page 20

17MODEL 6081-P pH/ORP SECTION 5.0 COMMISSIONINGSECTION 5.0COMMISSIONING5.1 Network Communications5.2 Device Network Configuration5.3 Verify Operation5

Page 21

18MODEL 6081-P pH/ORP SECTION 5.0 OPERATION WITH REMOTE CONTROLLER5.3 VERIFY OPERATIONOperation can be verified in three locations, at the device via

Page 22

19MODEL 6081-P pH/ORP SECTION 6.0 DISPLAY AND OPERATIONSECTION 6.0DISPLAY AND OPERATION6.1. DISPLAYThe Model 6081 has a two-linedisplay. Generally, t

Page 23 - SENSOR WIRING

About This DocumentThis manual contains instructions for installation and operation of the Model 6081-P Wireless pH/ORPTransmitter. The following list

Page 24

206.3 MENUS - pHThe Model 6081 pH transmitter has four menus: CALIBRATE, PROGRAM, SIM PV, and DISPLAY. Under theCalibrate and Program menus are sever

Page 25 - SECTION 4.0

21MODEL 6081-P pH/ORP SECTION 6.0 DISPLAY AND OPERATION6.5 SECURITY6.6.1 How the Security Code WorksUse security codes to prevent accidental or unwant

Page 26

22MODEL 6081-P pH/ORP SECTION 6.0 DISPLAY AND OPERATIONThis page left blank intentionally22

Page 27 - COMMISSIONING

23MODEL 6081-P pH/ORP SECTION 7.0OPERATION WITH MODEL 3757.1 Note on Model 375 HART Communicator7.2 Connecting the HART Communicator7.3 OperationSECT

Page 28 - 5.3 VERIFY OPERATION

247.3 Operation7.3.1 Off-line and On-line OperationThe Model 375 Communicator features off-line and on-line communications. On-line means the communic

Page 29 - DISPLAY AND OPERATION

25MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTERSECTION 8.0PROGRAMMING THE TRANSMITTER 8.1 General8.2 Changing Start-up Settings8.3

Page 30 - 6.2 KEYPAD

26MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.3 CHOOSING AND CONFIGURING THE ANALYTICAL MEASUREMENT8.3.1 PurposeThis section describes

Page 31 - 6.5 SECURITY

27MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.3.3 Procedure to configure: Measurement.To choose a menu item, move the cursor to the it

Page 32

28MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.4 CHOOSING TEMPERATURE UNITS AND MANUAL OR AUTOMATIC TEMPERATURECOMPENSATION8.4.1 Purpo

Page 33 - OPERATION WITH MODEL 375

29MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.5.2 Procedure: Setting a security code.1. Press MENU. The menu screen appears. Choose Pr

Page 34 - 7.3 Operation

QUICK START GUIDEFOR MODEL 6081 WIRELESS pH TRANSMITTERD1. Refer to Section 2.0 Installation for installation instructions.2 . Wire the pH or ORP s

Page 35 - PROGRAMMING THE TRANSMITTER

30MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.6 MAKING HART RELATED SETTINGSFor more information refer to Sec. 1.08.7 RESETTING FACTOR

Page 36 - Typically, the ref

31MODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER8.8 SELECTING A DEFAULT SCREEN AND SCREEN CONTRAST8.8.1 PurposeThis section describes how

Page 37

32This page left blank intentionallyMODEL 6081-P pH/ORP SECTION 8.0PROGRAMMING THE TRANSMITTER328.9 CHOOSING A DISPLAY TIMEOUT8.9.1 PurposeThe local t

Page 38 - COMPENSATION

33MODEL 6081-P pH/ORP SECTION 9.0CALIBRATION – TEMPERTURESECTION 9.0CALIBRATION — TEMPERATURE9.1 INTRODUCTIONThe Calibrate Menu allows the user to cal

Page 39 - 8.5 SETTING A SECURITY CODE

34MODEL 6081-P pH/ORP SECTION 9.0CALIBRATION – TEMPERTURE9.2.2 Procedure1. Remove the sensor from the process. Place it in an insulated container of w

Page 40

35MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PHSECTION 10.0CALIBRATION — pH AND ORP10.1 INTRODUCTIONFor pH sensors, two-point buffer calibration i

Page 41

36MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PHFIGURE 10-1. Calibration Slope and OffsetDuring automatic calibration, the transmitter also measures

Page 42

37MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PH10.2 PROCEDURE — AUTO BUFFER CALIBRATION1. Obtain two buffer solutions. Ideally, the buffer values

Page 43 - CALIBRATION — TEMPERATURE

3810.3 PROCEDURE — MANUAL TWO-POINT BUFFER CALIBRATION1. Obtain two buffer solutions. Ideally, the buffer values should bracket the range of pH valu

Page 44 - CALIBRATION – TEMPERTURE

39MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PH10.4 PROCEDURE — STANDARDIZATION1. The pH measured by the transmitter can be changed to match the

Page 45 - CALIBRATION — pH AND ORP

EQuick StartMenu English Francais Espanol >>Deutsch Italiano Portuguese >>Measure? pH Redox

Page 46 - CALIBRATION – PH

4010.5 PROCEDURE — ENTERING A KNOWN SLOPE VALUE.1. If the electrode slope is known from other measurements, it can be entered directly into the tran

Page 47 - The display will return

41MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PH10.6 ORP CALIBRATION10.6.1 Purpose1. For process control, it is often important to make the measured

Page 48

This page left blank intentionally42MODEL 6081-P pH/ORP SECTION 10.0CALIBRATION – PH

Page 49

43MODEL 6081-P pH/ORP SECTION 11.0MAINTENANCESECTION 11.0MAINTENANCE11.1 OVERVIEWThis section gives general procedures for routine maintenance of the

Page 50

44MODEL 6081-P pH/ORP SECTION 11.0MAINTENANCE11.3 pH SENSOR MAINTENANCE11.3.1 Frequency of CleaningThe frequency at which a sensor should be inspect

Page 51 - 10.6 ORP CALIBRATION

4511.3.3 Checking the Reference Electrode.Some processes contain substances, for example, sulfides, that poison the reference electrode. Poisoning al

Page 52

4611.4 ORP SENSOR MAINTENANCE11.4.1 Frequency of CleaningThe frequency at which an ORP sensor should be inspected and cleaned can be determined onl

Page 53 - MAINTENANCE

4711.6 POWER MODULE REPLACEMENTExpected power module (part number 00753-9220-0001) life is two years at reference conditions. This sectiondescribes t

Page 54 - 11.3 pH SENSOR MAINTENANCE

48This page left blank intentionally48MODEL 6081-P pH/ORP SECTION 11.0MAINTENANCE11.6.1 Handling ConsiderationsThe power module with the wireless unit

Page 55

49MODEL 6081-P pH/ORP SECTION 12.0 RETURN OF MATERIALSSECTION 12.0RETURN OF MATERIAL12.1 GENERAL.To expedite the repair and return of instruments, pro

Page 56 - 11.5 CALIBRATION

FFIGURE 1-1. MENU TREE FOR MODEL 6081 pH Wireless TRANSMITTER

Page 57 - 11.6 POWER MODULE REPLACEMENT

50This page left blank intentionallyMODEL 6081-P pH/ORP SECTION 12.0 RETURN OF MATERIALS

Page 58

51WARRANTYGoods and part(s) (excluding consumables) manufactured by Seller are warranted to be free from defects in workman-ship and material under no

Page 59 - RETURN OF MATERIAL

Credit Cards for U.S. Purchases Only.The right people,the right answers,right now.ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITEhttp://www.raihome.com

Page 60 - RETURN OF MATERIALS

MODEL 6081-P pH/ORP TABLE OF CONTENTSMODEL 6081-P pH/ORPWIRELESS TRANSMITTERTABLE OF CONTENTSSection Title Page1.0 DESCRIPTION AND SPECIFICATIONS ...

Page 61 - Irvine, CA 92606

MODEL 6081-P pH/ORP TABLE OF CONTENTSTABLE OF CONTENTS CONT’Dii8.0 PROGRAMMING THE TRANSMITTER.....

Page 62 - The right people

iiiMODEL 6081-P pH/ORP TABLE OF CONTENTSLIST OF FIGURESNumber Title Page2-1 Wall Mounting Insatallation Model 6081.........

Comments to this Manuals

No comments