7. Wall Control Procedures (continued)
7.3
Your wall control has code switches which must be set
in one of 32 possible code combinations (Figure 21).
The five levers (numbered 1, 2, 3, 4, and 5) on the
switches are factory-set in the ON (up) position.
Change the switch settings as follows:
7.4
Slide the five switch levers in the wall control to your
choice of ON (up) or down positions. Use a ball-point
pen or small screwdriver and slide the levers firmly up
or down.
7.5
The sixth switch marked ON and I is for dimming
control of lights: Set switch to ON to allow for dimming
of the lights. Set switch to I for no dimming of the lights
such as for fluorescent bulbs and non-dimming CFLs.
SINGLE-POLE INSTALLATION
WALL CONTROL
CODE SWITCHES
ON
1
23
4
5I
CODE
SWITCHES
WALL
CONTROL
Figure 21
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
FAN/LIGHT
WALL CONTROL
HOT BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
RECEIVER LOCATED ON
TOP OF THE CEILING
FAN
OFF ON
....
Figure 22
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WARNING
!
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
7.6
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan wall control into the outlet box.
7.7
Remove faceplate and screws from existing wall control.
Pull control out from the wall box. Determine the “hot”
wire and the “load” wire and disconnect these wires
from control (Figure 22). Do not attempt to disconnect
any wires not already connected to existing control.