CP200 Series
5
CLOSING SPRING
DIAPHRAGM
CONTROL SPRING
VALVE STEM
LEVER
PRESSURE RETAINING
PLUG (DO NOT REMOVE)
TYPE 67CP PRESSURE
LOADING REGULATOR
SECONDARY SEAT™ DETAIL
INLET PRESSURE
OUTLET PRESSURE
ATMOSPHERIC PRESSURE
LOADING PRESSURE
Type CP206 Secondary Seat Protection
with Bleed
The Type CP206 provides small bleed to the downstream
system as an indication that the Secondary Seat is providing
lockup. In the event that the primary orice and disk cannot
provide lockup, the secondary seating surface will move into
contact with a metal disk. This metal to metal interface will
allow a small amount of gas to bleed downstream thereby
increasing outlet pressure until the Internal Token relief
valve begins to discharge a small amount of gas to the
atmosphere. The odor of this discharged gas provides an
indication that the regulator is relying on the Secondary Seat
for overpressure protection.
Types CP205 and CP206 Secondary Seat
Protection Limitations
CAUTION
Overpressure conditions can occur in the
downstream piping when the Secondary Seat
Protection is installed. The Secondary Seat
Protection serves only as a backup to the
primary seat for lockup. Refer to the sections
on Overpressure Protection and Maintenance.
4
CP200 Series with Secondary Seat
TM
Protection
CONTROL SPRING
RELIEF V LVE STEM
VALVE STEM
SECONDARY SEAT DETAIL
M1165
Figure 3. Type CP205IT Pressure Loaded Pressure Reducing Regulator with Internal Registration and Token Relief Operational Schematic
PRIMARY DISK
NORMAL OPERATION
NORMAL LOCKUP
DEBRIS OBSTRUCTING
LOCKUP
SECONDARY SEAT
LOCKUP
TYPE CP206
SECONDARY SEAT WITH
METAL TO METAL BLEED
PRIMARY ORIFICE
SEATING SURFACE
SECONDARY
SEATING SURFACE
METALLIC SECONDARY ORIFICE
SEATING SURFACE
SECONDARY SEAT DETAILED VIEW
ELASTOMERIC SECONDARY
SEATING SURFACE