Emerson MICRO MOTION 2700 User Manual

Browse online or download User Manual for Unknown Emerson MICRO MOTION 2700. Modbus® Mapping Assignments for Micro Motion® Transmitters

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
www.micromotion.com
Instruction Manual
P/N 3600283, Rev. C
July 2002
Modbus
®
Mapping
Assignments for Micro
Motion
®
Transmitters
Page view 0
1 2 3 4 5 6 ... 34 35

Summary of Contents

Page 1 - Transmitters

www.micromotion.comInstruction ManualP/N 3600283, Rev. CJuly 2002Modbus® Mapping Assignments for Micro Motion® Transmitters

Page 2

4 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continuedTable 2-2. RFT9739 security coilsAddress Description R

Page 3

Modbus® Mapping Assignments for Micro Motion® Transmitters 5Modbus Mapping Assignments continuedTable 2-3. Read-only discrete inputsAddress Descriptio

Page 4

6 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued2 0187 0188 Volume flow minimum rangeÖÖÖÖ2 0189 0190 F

Page 5 - Contents

Modbus® Mapping Assignments for Micro Motion® Transmitters 7Modbus Mapping Assignments continued2 0247 0248 Mass flow rateÖ ÖÖÖ2 0249 0250 DensityÖ ÖÖ

Page 6

8 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued2 0513 0514 T-Series DTG valueÖÖÖ2 0515 0516 T-Series

Page 7 - 1 Using the Modbus Map

Modbus® Mapping Assignments for Micro Motion® Transmitters 9Modbus Mapping Assignments continued2 0815 0816 Slot 16 process variableÖÖÖ2 0817 0818 Slo

Page 8 - What this document does

10 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued3 0005 Volume flow rate scaled integerÖÖÖÖ3 0008 Mass

Page 9 - 2 Modbus Mapping Assignments

Modbus® Mapping Assignments for Micro Motion® Transmitters 11Modbus Mapping Assignments continued3 0310 High-order word for binary volume totalÖ33 031

Page 10 - continued

12 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued3 0422 Bit #0 API: Temperature outside standard range

Page 11

Modbus® Mapping Assignments for Micro Motion® Transmitters 13Modbus Mapping Assignments continued3 1137 Core processor software revisionÖÖ3 1138 Outpu

Page 13

14 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued4 0049 Final assembly number – low order register of

Page 14

Modbus® Mapping Assignments for Micro Motion® Transmitters 15Modbus Mapping Assignments continued4 0680 Slot 25 configuration indexÖÖÖ4 0681 Slot 26 c

Page 15 - Table 2-5. Input registers

16 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued4 1124 Display variable #8ÖÖ4 1125 Display variable #

Page 16

Modbus® Mapping Assignments for Micro Motion® Transmitters 17Modbus Mapping Assignments continuedTable 2-7. ASCII character stringsNoteAlways write ch

Page 17

18 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued55555555555555550104010501060107010801090110011101120

Page 18

Modbus® Mapping Assignments for Micro Motion® Transmitters 19Modbus Mapping Assignments continuedTable 2-8. Integer codesMVDSoloSeries 1000Series 2000

Page 19 - Table 2-6. Holding registers

20 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continuedBase time unit codes for special mass units (holding

Page 20

Modbus® Mapping Assignments for Micro Motion® Transmitters 21Modbus Mapping Assignments continuedBase volume units for special volume units (holding r

Page 21

22 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continuedMilliamp output variable codes (holding register 4001

Page 22

Modbus® Mapping Assignments for Micro Motion® Transmitters 23Modbus Mapping Assignments continuedQuaternary variable codes (holding register 40015)0 M

Page 23

Modbus® Mapping Assignments for Micro Motion® TransmittersJuly 2002For technical assistance, phone the Micro Motion Customer Service Department:• In t

Page 24

24 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued33 API: CTLÖÖÖ34 High-order doubleword of binary mass

Page 25 - Table 2-8. Integer codes

Modbus® Mapping Assignments for Micro Motion® Transmitters 25Modbus Mapping Assignments continuedFlow tube liner material codes (holding register 4013

Page 26

26 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continued9 ANSI 900ÖÖÖÖ10 Sanitary clampÖÖÖÖ11 UnionÖÖÖÖ12 PN

Page 27

Modbus® Mapping Assignments for Micro Motion® Transmitters 27Modbus Mapping Assignments continuedPolling control option codes (holding register 40302

Page 28

28 Modbus® Mapping Assignments for Micro Motion® TransmittersModbus Mapping Assignments continuedBurst variable codes for command 33 (holding register

Page 29

recycled paperMicro Motion Inc. USAWorldwide Headquarters7070 Winchester CircleBoulder, Colorado 80301Tel (303) 530-8400(800) 522-6277Fax (303) 530-84

Page 31

Modbus® Mapping Assignments for Micro Motion® Transmitters iContents1 Using the Modbus Map . . . . . . . . . . . . . . . . . . . . . . . 11.1 What thi

Page 32

ii Modbus® Mapping Assignments for Micro Motion® Transmitters

Page 33

Modbus® Mapping Assignments for Micro Motion® Transmitters 11 Using the Modbus Map1.1 What this document tells youThis document lists Modbus® mapping

Page 34

2 Modbus® Mapping Assignments for Micro Motion® TransmittersUsing the Modbus Map continuedWhat this document does not tell youThis document does not e

Page 35 - *3600283*

Modbus® Mapping Assignments for Micro Motion® Transmitters 32 Modbus Mapping AssignmentsTable 2-1. Read/write coilsAddress Description MVDSoloSeries 1

Comments to this Manuals

No comments