www.Fisher.comBaumannt 84000 Sanitary DiaphragmAngle and Inline Control ValveContentsIntroduction 1...Scope of Manual 1.
84000 ValveInstruction ManualJune 201010E1320E1321NPS 11/2 AND 2 ANGLE VALVE BODY (RECOMMENDED FOR PROCESSESWHERE ATMOSPHERIC OR SLIGHT VACUUM IS PRE
84000 ValveInstruction ManualJune 201011E1322216 (48.5)249 (9.8)BAUMANN 32 ACTUATOR WITHFIELDVUE DVC2000, TOP VIEW216 (48.5)31 (1.24)229(9.0)85(3.4)
84000 ValveInstruction ManualJune 201012E1323279 (411.0)359 (14.5)276(10.9)NOTE: ACTUATOR REMOVAL REQUIRES 115mm (4.5 INCHES) VERTICAL CLEARANCE. FOR
84000 ValveInstruction ManualJune 20102WARNINGAlways wear protective gloves,clothing and eyewear when performingany installation operations to avoidpe
84000 ValveInstruction ManualJune 20103MaintenanceWARNINGAvoid personal injury and propertydamage from sudden release ofprocess pressure or bursting o
84000 ValveInstruction ManualJune 20104Air Piping1. For an airtoextend actuator (airtocloseaction), connect the actuating air pressure line to th
84000 ValveInstruction ManualJune 201054. IMPORTANT: Verify that the recessed rollerbearings in the drive mechanism (key 4) rest againstthe flats of
84000 ValveInstruction ManualJune 20106DIAPHRAGM (key 8) by tightening 1/2turn. DO NOT tighten to the point thatthe diaphragm wrinkles.Calibration of
84000 ValveInstruction ManualJune 20107E1314Figure 4. Baumann 84000 NPS 1 Angle Valve BodySubAssemblyE1315Figure 5. Baumann 84000 NPS 1 Inline Valve
84000 ValveInstruction ManualJune 20108Table 1. Common PartsKEYNO.QTY DESCRIPTIONVALVE SIZENPS 1 Angle NPS 1 Inline NPS 11/2 Angle NPS 2 Angle1 1Valv
84000 ValveInstruction ManualJune 20109E1318E1319NPS 1 ANGLE VALVE BODY POSITIONED FORFORWARD FLOW SELF DRAINING FROM PORT A TO BNPS 1 INLINE VALVE BO