Emerson 1F98EZ-1421 User's Guide Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
USING YOUR THERMOSTAT
System Operation
Temporary Temperature Hold
You can temporarily adjust the tem-
perature in your home at any time while
your thermostat is running a program by
touching either
or keys. The dis-
play will indicate “Temporary Hold At”
to the left of the setpoint temperature. To
cancel the temporary setting before the
next period begins, touch Run Schedule
to return to the program.
Example: If you turn up the heat during
the Morning program, it will remain at the
new temperature until the time for the
next program period (Day program).
Touch the SYSTEM key to select the
thermostat operating mode desired.
When the system is calling for first stage
heat or cool, “Low” will display on the
touchscreen. When second stage is re-
quired, the display will show “High”. The
setpoint temperature can be changed by
touching the
or keys.
Auxiliary Heating
Heat Pump Only
The system automatically activates
Auxiliary Heating when the outside tem-
perature is too cold for the heat pump to
efficiently heat the home. When Auxiliary
Heating is called for, the display will show
“Auxiliary Heat”.
Emergency Heating
Heat Pump Only
Heat pump malfunction is rare, but
should it happen, Emergency Heat can
be manually activated by touching the
SYSTEM key to
Em. This will start the
electric or fossil fuel system to provide
heat. The display will show “Auxiliary
Heat”.
USAGE GUIDE
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20

Comments to this Manuals

No comments