Data/Signal Line Protection
Features
Tip to ring protection
Tip, ring to ground protection
Solid state over-current protection
Resettable fusing — PTCs
UL 497A listed
5 year warranty
General Technical Specifications
Edco NET Series
SIECOR Network Interface Device
The Edco NET Series is a SIECOR Network Interface Line Module with built-in
secondary surge protection. In addition to silicon breakover clamping
technology (over-voltage), the Edco NET Series incorporates state-of-the-art
resettable over-current protection devices — PTCs.
The over-current circuitry allows normal telephone currents to pass, but quickly
switches to a high impedance state when subjected to extended over-currents
that can damage telephone system line cards.
Part Number Edco NET-015T
Max. Peak Signal Voltage 12
Nominal Breakdown Voltage 15
Max Peak Pulse Current
Ip 10 X 1000 µs 124
Typ Cap (pf) 2100
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Part Number Edco NET-030T
Max. Peak Signal Voltage 24
Nominal Breakdown Voltage 30
Max Peak Pulse Current
Ip 10 X 1000 µs 71
Typ Cap (pf) 1180
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Part Number Edco NET-050T
Max. Peak Signal Voltage 43
Nominal Breakdown Voltage 50
Max Peak Pulse Current
Ip 10 X 1000 µs 45
Typ Cap (pf) 900
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Part Number Edco NET-060T
Max. Peak Signal Voltage 52
Nominal Breakdown Voltage 60
Max Peak Pulse Current
Ip 10 X 1000 µs 36
Typ Cap (pf) 750
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Part Number Edco NET-200T
Max. Peak Signal Voltage 180
Nominal Breakdown Voltage 230
Max Peak Pulse Current
Ip 10 X 1000 µs 200A (T-G)+ (R-G)
Typ Cap (pf) 150
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Part Number Edco NET-TEL
Max. Peak Signal Voltage 220
Nominal Breakdown Voltage 270
Max Peak Pulse Current
Ip 10 X 1000 µs 200A (T-G)+ (R-G)
Typ Cap (pf) 150
Max Continuous Current 150ma
Nominal Series Resistance 8 Ohms
Installation
Notes:
A. Never install telephone wiring during a
lightning storm.
B. Protectors are intended for indoor or outdoor
use within a network interface device
(Siecor CAC 7600).
C. If any visible damage has occurred to module,
turn off power before attempting to remove or
insert another module.
D. Install in accordance with the NEC, Article 800.