Emerson SW93 Owner's Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
32
General
This control is designed to operate
two ceiling fans, and not any
accessory light kits. This SW93
speed control is rated for 3.0 amps
at 120 volts. To avoid erratic speeds
and possible damage to your ceiling
fan, use this control only with the
fans pull chain switches set to their
high speed settings.
Installation
1. Before disconnecting power,
ensure that the fan is set at the
highest speed.
NOTE: Electric connections
should be in accordance with the
National Electrical Codes and all
Local Codes. Before starting,
disconnect power to the circuit at
the fuse box or circuit breaker
panel.
2. Remove the faceplate and
screws from the existing wall
switch. Pull switch out from wall
outlet box.
3. Disconnect wire from existing fan
wall switch (Figure 1).
4. Set the SW93 Quietset Dual Fan
Control in the off position (full
counter-clockwise), and pull off
the knob.
Safety Instructions
WARNING: To avoid fire, shock, and serious personal injury,
follow all instructions carefully.
1.Read your Owner's Manual carefully. Retain Owner’s Manual for
future reference.
2.To avoid possible electrical shock, be sure electricity is turned off
at the main fuse or circuit breaker box before wiring.
3.Make certain no bare wires are exposed outside the wire
connectors.
4.Do not mount speed control near heat producing equipment.
5.All wiring must conform to National and Local Electrical Codes. If
you do not have enough electrical knowledge, have a licensed
electrician install the control.
WARNING: Use of this control with some ceiling fans could result
in fire, shock and serious personal injury. Use this speed control
only with Emerson CF series ceiling fans.
7. Position the faceplate (not
provided) onto the speed control.
Using the two 6-32 screws
supplied with the faceplate, screw
the faceplate and speed control
to the wall outlet box (Figure 3).
8. Press knob onto the shaft and
rotate counter-clockwise to the
full-OFF position.
9. Restore power at the main fuse
box or circuit breaker panel.
CAUTION
For fans equipped with built-in
variable speed devices: These
devices must be set at their
MAXIMUM SPEED for proper
operation. Adjustments to their
setting must only be made with
Quietset in the OFF position.
Changing or switching these
settings while the fan control is in
operation could damage the
control.
FACEPLATE
SWITCH
WALL
OUTLET
BOX
Figure 1
5. Connect the BLACK wire from
the Quietset to the fan/motor lead
with a wire connector (provided).
(Figure 2.)
6. Connect the BLACK wire from
the Quietset to the 120VAC hot
wire with a wire connector
(provided).
NOTE: Use wire connectors
(supplied) to secure electrical
connections.
TO NEUTRAL
TO FAN MOTOR LOAD
MOTOR LOAD
1.25 AMP MAXIMUM
TO 120VAC
SOURCE HOT
BLACK
BLACK
Figure 2
FACEPLATE
QUIETSET SPEED
CONTROL
WALL OUTLET
BOX
6-32 SCREWS (2)
Figure 3
Page view 1
1 2

Comments to this Manuals