Emerson ACE97 Datasheet Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
Bulletin 74.3:ACE97
14

In order to complete the specification worksheet, the following information must be provided.  Operating pressures and temperatures 
must be within the ranges listed within this bulletin.
 Imperial (USA) _____ or Metric _____

    1.  Maximum Inert Gas Flow - SCFH or Nm3/hr: _____________ or Pad Valve Cv: _____________
    2.  Inert Gas: _____________ or Inert Gas Specific Gravity: _____________
    3.  Supply Pressure, Inert Gas - Maximum: _____________ Minimum: _____________
    4.  Operating Temperature - °F: _____________ or °C: _____________
    5.  Pad Setpoint: _____________ inches w.c. or mbar

    6.  Maximum Vent Gas Flow - SCFH or Nm
3
/hr: _____________ or Depad Valve C
v
: _____________
    7.  Vent Gas Specific Gravity: _____________
    8.  Vent Gas Temperature - °F: _____________ or °C: _____________
    9.  Depad Setpoint: _____________ inches w.c. or mbar
  10.  Relief Header Pressure at Depad Outlet, Flowing Conditions, Maximum: _________ inches w.c. or mbar
  11.  Stored Liquid Flash Point - °F: _____________ or °C: _____________ or 
    Stored Liquid Boiling Point - °F: _____________ or °C: _____________ (Require at least one for API sizing)
  12.  Storage Temperature of Product - °F: _____________ or °C: _____________
  13.   Depad Materials of Construction Compatible with Stored Liquid and Vapors Metals:  316 SST or _____________
    Elastomers:  Nitrile (NBR) _____, Fluorocarbon (FKM) _____, Ethylenepropylene (EPDM-FDA) _____,  
    Perfluoroelastomer (FFKM)  _____, or Other  __________________
  14.  Product to be Blanketed: _____________
  15.  Optional Equipment Required: _____________
  16.  Emergency Pressure Vent Setpoint: _____________ inches w.c. (separate device)

  17.  Inert Gas Supply -          NPT: ___________  Flanged: ___________   Other (specify): ___________
  18.  Tank Connection -          NPT: ___________  Flanged: ___________   Other (specify): ___________
  19.  Header Connection -     NPT: ___________  Flanged: ___________   Other (specify): ___________
Notes
  If the required Pad or Depad valve C
v
 value is unknown, refer to the Sizing section for more details or contact your local Sales Office.  
  If the required Pad or Depad valve C
v
 value is known, continue with the Ordering worksheet.