Emerson Y690A Datasheet Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Bulletin 74.1:Y690A
2
Specications
Available Congurations
Type Y690A: Direct-operated pressure reducing
regulator for outlet pressures up to 7-inches w.c.
(17 mbar) equipped with a pitot tube for greater
regulated capacities.
Type Y690AH: Direct-operated pressure
reducing regulator for outlet pressures up to
7 psig (0,48 bar) equipped with a pitot tube for
greater regulated capacities.
Type Y690AM: Direct-operated pressure
reducing regulator for outlet pressures up to
7-inches w.c. (17 mbar) equipped with a
blocked throat and O-ring stem seal. The
lower diaphragm casing is tapped 1/2 NPT for
control line connection.
Type Y690AHM: Direct-operated pressure
reducing regulator for outlet pressures up to
7 psig (0,48 bar) equipped with a blocked
throat and O-ring stem seal. The lower
diaphragm casing is tapped 1/2 NPT for
control line connection.
Body Sizes
NPS 3/4 or 1 (DN 20 or 25)
End Connection Styles
See Table 1
Maximum Allowable Inlet Pressure
(1)
150 psig (10,3 bar)
Maximum Operating Inlet Pressure
(1)
See Table 4
Maximum Outlet Pressure (Casing)
(1)
150 psig (10,3 bar)
Maximum Emergency Outlet Pressure to Avoid
Internal Parts Damage
(1)
150 psig (10,3 bar)
Outlet Pressure Ranges
(1)
See Table 5
Orice Sizes and Flow and Sizing Coefcients
See Table 2
Pressure Registration
Types Y690A and Y690AH: Internal
Types Y690AM and Y690AHM: External
Flow Capacities
See Tables 9 and 10
Construction Materials
See Table 3
Material Temperature Capabilities
(1)
Nitrile (NBR):
-20° to 180°F (-29° to 82°C)
Fluorocarbon (FKM):
40° to 300°F (4° to 149°C)
Ethylenepropylene (EPDM):
-20° to 275°F (-29° to 135°C)
Peruoroelastomer (FFKM):
-20° to 300°F (-29° to 149°C)
Pressure Setting Adjustment
Adjusting Screw
Spring Case Connection
1/4 NPT
Diaphragm Case Connection
1/2 NPT
Approximate Weight
19 pounds (9 kg)
1. The pressure/temperature limits in this Bulletin and any applicable standard or code limitation should not be exceeded.
Page view 1
1 2 3 4 5 6 7 ... 15 16

Comments to this Manuals

No comments