ACE95 Series
7
Table 3. Type ACE95 Diagnostics Table: C
v
1 through 4, Inlet Pressure Range Spring 25 to 50 psig (1,7 to 3,4 bar)
25 (1,7) 24 (1,7) 9 (0,62) 2 (0,14)
30 (2,1) 29 (2,0) 13 (0,90) 6 (0,41)
35 (2,4) 34 (2,3) 16 (1,1) 9 (0,62)
40 (2,8) 39 (2,7) 20 (1,4) 13 (0,90)
45 (3,1) 44 (3,0) 24 (1,7) 17 (1,2)
50 (3,4) 49 (3,4) 28 (1,9) 21 (1,4)
Table 4. Type ACE95 Diagnostics Table: C
v
1 through 4, Inlet Pressure Range Spring 51 to 120 psig (3,5 to 8,3 bar)
51 (3,5) 50 (3,4) 29 (2,0) 5 (0,35)
60 (4,1) 59 (4,1) 36 (2,5) 12 (0,83)
70 (4,8) 69 (4,8) 43 (3,0) 19 (1,3)
80 (5,5) 79 (5,4) 51 (3,5) 27 (1,9)
90 (6,2) 89 (6,1) 59 (4,1) 34 (2,3)
100 (6,9) 99 (6,8) 66 (4,6) 42 (2,9)
110 (7,6) 109 (7,5) 74 (5,1) 50 (3,4)
120 (8,3) 119 (8,2) 81 (5,6) 57 (3,9)
It is recommended that all seals and diaphragms be
replaced as a matter of good practice whenever a
valve is disassembled and re-assembled. Parts kits
are available through your local Sales Ofce.
If you are performing disassembly or assembly operations
on a Type ACE95Sr valve, refer to the Parts List and see
Figure 9. If you are working on a Type ACE95 valve, refer
to the Parts List and see Figure 8.
Spring Case Disassembly
1. Remove the actuator cap (key 1) and the spring load
by unthreading the adjusting screw (key 2).
See Figure 5.
2. Unthread the hex-head screws, lock washers,
and nuts (keys 32, 28, and 31) from the upper and
lower actuator cases (keys 33 and 30). Lift the
upper actuator case from the lower actuator case.
3. Remove the spring seat and range spring
(keys 5 and 8).
!
Comments to this Manuals