Emerson Liebert MicroPOD Maintenance Bypass and Output Distribution Accessory User's Guide

Browse online or download User's Guide for Uninterruptible power supplies (UPSs) Emerson Liebert MicroPOD Maintenance Bypass and Output Distribution Accessory. Emerson Liebert MicroPOD Maintenance Bypass and Output Distribution Accessory User Guide [et] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
POWER AVAILABILITY
3U POD
USER MANUAL
Power Output
Distribution
208 Volt
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - USER MANUAL

POWER AVAILABILITY3U POD™USER MANUALPower OutputDistribution208 Volt

Page 2 -

6INDICATOR LAMPSUTILITY Indicator LampThis orange lamp is illuminated when utility power is present (see Figure 5). It signals that you may transfer

Page 3 - TABLE OF CONTENTS

7OPERATIONTransfer to Maintenance BypassTo transfer to maintenance bypass (utility) from UPS, use the following steps:1. Ensure the UTILITY lamp (ora

Page 4

8SPECIFICATIONS This 3U POD is intended for use with a UPS meeting all the following requirements: • UPS input cord is compatible with the rating and

Page 5 - SAVE THESE INSTRUCTIONS

9TROUBLESHOOTINGProblem Cause SolutionUTILITY lamp (orange) not illuminated.Utility not present. Call qualified service personnel to restore power to

Page 8 - INSTALLATION AND START-UP

The Company Behind the ProductsWith over a million installations around the globe,Liebert is the world leader in computer protectionsystems. Since its

Page 10 - INDICATOR LAMPS

iTABLE OF CONTENTSIMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1GLOSSARY OF SYM

Page 12 - SPECIFICATIONS

1IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important instructions that should be followed during installation and oper

Page 13 - TROUBLESHOOTING

2GLOSSARY OF SYMBOLS•Indicates AC Input.Indicates AC Output.Consult the manual for additional information.UTILITY lamp indicates local power is avail

Page 14

3INTRODUCTION AND SYSTEM DESCRIPTIONCongratulations on your choice of the Liebert 3U POD™. The Liebert 3U POD provides main-tenance bypass capability

Page 15

4INSTALLATION AND START-UPUnpack and Inspect the 3U POD1. Unpack the 3U POD carefully, noting the packing method. Retain the box and packing material

Page 16 - USER MANUAL

5Start Up the POD1. If you already have a UPS installed, turn off all connected loads and unplug them from the UPS. Turn off the UPS and disconnect th