Page view 6
7
ViSSion® 20/20 Retro t Instructions • 35391SCRF
NOTE
Stainless steel tubing is not provided in a retro t kit.
Step 10. Route stainless steel tubing from suction manifold, discharge manifold and oil lter inlet lines. If existing
tubing is not reusable then cables can be secured to block and bleed assembly (4).
NOTE
Wells are also provided in retro t kit. Install new wells as required.
Step 11. Install RTDs (8) on suction manifold (9), discharge manifold (11), oil separator (12) and inlet oil line (14)
or oil manifold (13), if equipped.









Figure 5. Compressor Unit RTD Locations
Step 12. Connect cables (10) to RTDs (8).