Emerson CMF200A User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
Micro Motion
®
2-Wire Coriolis Flow and Density Meters 11
Weight
Micro Motion adapter-barrier
kg
Sensor and transmitter
(1)
(1) Weight of sensor and polyurethane-painted aluminum transmitter with ANSI CL150 welded flanges. For stainless steel transmitter,
add 2 kg.
CMF025 6
CMF050 8
CMF100 16
CMF200 31
Adapter-barrier 0,15
The Micro Motion adapter-barrier provides Class I, Div. 1 and Zone 1 intrinsic safety protection, and re-spans the I/O signal
from 12–20 mA to 4–20 mA.
Transmitter to host with no barrier
Transmitter to host with third-party barrier
Transmitter to host with Micro Motion adapter-barrier
mA receiving
device
DCS
12–20 mA HART
2-wire connection
Model 2200S
mA receiving
device
DCS
12–20 mA HART
Safe area Hazardous area
3rd-party barrier
2-wire connection
Model 2200S
mA receiving
device
DCS
4–20 mA HART
Safe area Hazardous area
Adapter-barrier
2-wire connection
Model 2200S
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 23 24

Comments to this Manuals

No comments