Installation
NOTE: Installation of this control
requires that a three-conductor cable
with ground wire be run between the
control wall box and the ceiling fan
outlet.
1. After electricity has been turned off at
the main fuse box or circuit breaker
panel, remove the existing wall plate
and switch (Figure 1).
Safety Instructions
WARNING: To avoid fire, shock, and serious personal injury, follow all
instructions carefully.
1. Read your Owner's Manual carefully before installing the fan/light control.
Retain Owner's Manual for future reference.
2. To avoid possible electrical shock, be sure electricity is turned off at the
main fuse box or circuit breaker panel before wiring.
3. Make certain no bare wires are exposed outside the wire connectors.
4. Do not mount the fan/light control near heat producing equipment.
5. All wiring must conform to National and Local Electrical Codes. If you feel
you do not have enough electrical wiring knowledge or experience, have
your fan/light control installed by a licensed electrician. Any electrical work
not described in this manual should be performed by a licensed electrician.
6. Use of this control with some ceiling fans could result in fire, shock and
serious personal injury. Use this fan/light control only with capacitor speed
controlled ceiling fans.
2. Set all knobs on the fan/light control in
the off (down) position (Figure 2).
3. Make the following wire connections
(Figure 2) and secure with wire
connectors supplied:
Black wire from fan to black wire from
fan/light control.
White wire from fan to white wire
from the 120V AC supply source.
Blue wire from fan to blue wire from
fan/light control.
Black/white wire from fan/light control
to black wire from the 120V AC
supply source.
NOTE: Refer to Schematic “A” or “B”,
depending upon the location of your
120V AC supply source.
To avoid possible electrical shock,
be sure electricity is turned off at
the main fuse box or circuit
breaker panel before installing the
fan/light.
OUTLET BOX
SWITCH
WALL PLATE
EMERSON
TO HOT
BLACK/WHITE
SPEED
SWITCH
BLACK SPEED CONTROL LEAD
LIGHT
SWITCH
BLUE LIGHT SWITCH LEAD
BACK VIEW
4
3
2
1
DASH LINES ARE 3
CONDUCTOR CABLE
W/GROUND WIRE
BETWEEN CEILING
AND WALL OUTLET
BOXES
120V AC
SUPPLY
SOURCE
BLACK
WHITE
GROUND
GREEN
WHITE
BLACK
BLUE
WALL OUTLET
BOX GROUND
BLUE
BLACK
BLACK/WHITE
FAN/LIGHT
CONTROL
CEILING OUTLET BOX
Figure 1
Figure 2
Schematic “A”
CONNECTIONS REQUIRED WHEN SUPPLY VOLTAGE IS FED INTO CEILING
OUTLET BOX.
DASH LINES ARE 3
CONDUCTOR CABLE
W/GROUND WIRE
BETWEEN CEILING
AND WALL OUTLET
BOXES
GREEN
WHITE
BLACK
BLUE
120V AC
SUPPLY
SOURCE
BLACK
WHITE
GROUND
BLUE
BLACK
FAN/LIGHT
CONTROL
BLACK/WHITE
CEILING
OUTLET
BOX
Schematic “B”
CONNECTIONS REQUIRED WHEN SUPPLY VOLTAGE IS FED INTO WALL
OUTLET BOX.