Y696VR Series
D102662X012
Instruction Manual
Form 5480
June 2009
www.emersonprocess.com/regulators
Y696VR Series Vacuum Regulators
Figure 1. Type Y696VR Vacuum Regulator
W7431
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage andpersonal
injury or death.
Fisher
®
regulators must be installed,
operated, and maintained in accordance
with federal,state, and local codes, rules
and regulations, and Emerson Process
Management RegulatorTechnologies Inc.
instructions.
If the regulator vents gas or a leak
develops in the system, service to the
unit may be required. Failure to correct
trouble could result in a hazardous
condition.
Installation, operation, and maintenance
procedures performed by unqualied
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use qualied
personnel when installing, operating, and
maintaining the Y696 Series regulator.
Introduction
Scope of Manual
This manual describes and provides instructions and
parts lists for the Type Y696VR and the Type Y696VRM
vacuum regulators. Instructions and parts lists for
other equipment used with these breakers are found in
separate manuals.
Product Description
The Y696VR Series direct-operated vacuum regulators
are used for precise control of small capacity, low-
pressure service applications where an increase in
vacuum must be limited. They are described as follows:
Type Y696VR—The Type Y696VR has internal pressure
registration requiring no downstream control line.
Type Y696VRM—The Type Y696VRM has a control
line connection and an O-ring stem seal blocking the
throat for external pressure registration.
Specications
Some general ratings and specications for the
Y696VR Series vacuum regulators are given on page 2.
Individual regulators from the factory are supplied with
the specic data stamped on the nameplate.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Y696VR Series

Y696VR Series D102662X012Instruction ManualForm 5480June 2009www.emersonprocess.com/regulatorsY696VR Series Vacuum RegulatorsFigure 1. Type Y696VR Vac

Page 2

Y696VR Series 2SpecicationsBody Sizes and End Connection Styles(1)See Table 1Maximum Allowable Emergency Inlet (Casing) Pressure(2)±15 psig (±1,03 ba

Page 3

Y696VR Series 3NoteIf this equipment is shipped mounted on another unit, install the unit according to the appropriate instruction manual. 1. Only p

Page 4

Y696VR Series 4These procedures are for gaining access to the disk assembly, orice, and body gasket. All pressure must be released from the diaphrag

Page 5

Y696VR Series 5 diaphragm head (key 24), diaphragm (key 5), and upper diaphragm head (key 6) on the pusher post (key 8) and attach

Page 6

Y696VR Series 6Parts ListKey Description Part Number1 Spring 1 to 3-inches w.c. (2 to 7 mbar) 1D892527022 1-1/2 to 5-inches w.c. (4 to 12 mb

Page 7

Y696VR Series 7A7176TYPE Y696VRM BODY AND STEM ASSEMBLY DETAILA7175TYPE Y696VR ASSEMBLYFigure 3. Types Y696VR and Y696VRM Vacuum Regulator Assemblies

Page 8

Y696VR Series The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. F