Y695A Series
D102596X012
Instruction Manual
Form 5466
February 2010
This manual provides instructions for installation, startup,
maintenance, and parts information for the Y695A Series
vapor recovery regulators. Instructions and parts lists for
other equipment used with these regulators are found in
separate manuals.
Specications for the Y695A Series vapor recovery
regulators are listed on page 2. Specications for a given
regulator as it originally comes from the factory are stamped
on the nameplate.
The Y695A Series vapor recovery regulators are direct-
operated. They are used to sense an increase in vessel
pressure and vent excessive internal vessel pressure to an
appropriate vapor recovery disposal or reclamation system.
They may also be used as backpressure regulators or
relief valves.
The Type Y695A has internal registration
requiring no downstream control line.
The Type Y695AM has a blocked throat and
a downstream control line connection for external registration.
The Y695A Series vapor recovery regulators are
used to maintain a constant inlet (blanket) pressure with
the outlet owing to a system whose pressure is lower than
that at the inlet. When vessel pressure increases above the
setpoint of the regulator due to pumping in or thermal heating,
the force of the control spring is overcome by pressure
acting on the diaphragm. This moves the disk away from
the orice, allowing gas to ow from the vessel to the vapor
recovery system. As vessel pressure is reduced, the force
of the back disk spring causes the disk to move toward the
orice, decreasing the ow of gas out of the vessel. As vessel
pressure drops below the setpoint of the regulator, the disk will
seat against the orice, shutting off the gas ow.
!
Figure 1. Type Y695A Vapor Recovery Regulator
W7381