Y695A Series
D102596X012
Instruction Manual
Form 5466
February 2010




This manual provides instructions for installation, startup,
maintenance, and parts information for the Y695A Series
vapor recovery regulators. Instructions and parts lists for
other equipment used with these regulators are found in
separate manuals.

Specications for the Y695A Series vapor recovery
regulators are listed on page 2. Specications for a given
regulator as it originally comes from the factory are stamped
on the nameplate.

The Y695A Series vapor recovery regulators are direct-
operated. They are used to sense an increase in vessel
pressure and vent excessive internal vessel pressure to an
appropriate vapor recovery disposal or reclamation system.
They may also be used as backpressure regulators or
relief valves.
The Type Y695A has internal registration
requiring no downstream control line.
The Type Y695AM has a blocked throat and
a downstream control line connection for external registration.

The Y695A Series vapor recovery regulators are
used to maintain a constant inlet (blanket) pressure with
the outlet owing to a system whose pressure is lower than
that at the inlet. When vessel pressure increases above the
setpoint of the regulator due to pumping in or thermal heating,
the force of the control spring is overcome by pressure
acting on the diaphragm. This moves the disk away from
the orice, allowing gas to ow from the vessel to the vapor
recovery system. As vessel pressure is reduced, the force
of the back disk spring causes the disk to move toward the
orice, decreasing the ow of gas out of the vessel. As vessel
pressure drops below the setpoint of the regulator, the disk will
seat against the orice, shutting off the gas ow.

!




















Figure 1. Type Y695A Vapor Recovery Regulator
W7381
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Y695A Series

Y695A SeriesD102596X012Instruction ManualForm 5466February 2010

Page 2

Y695A Series2 NPS 3/4 or 1 (DN 20 or 25) See Table 2 150 psi

Page 3

Y695A Series3INLET PRESSUREOUTLET PRESSUREATMOSPHERIC PRESSUREFigure 2. Type Y695A Operational SchematicB2648 and to collect tank vapors for the v

Page 4

Y695A Series4This procedure is for gaining access to the disk assembly, orice, and body seal O-ring. All pressure must be released from the

Page 5

Y695A Series5 Diaphragm head (key 7) Lower spring seat (key 50) Washer (key 36) Diaphragm plate cap screws (key 38) Secure usin

Page 6

Y695A Series6Table 2. Body Materials and Part Numbers (Body, key 1)  

Page 7

Y695A Series7224 46 47Figure 4. Types Y695A and Y695AM Assembly DetailB2649_1Figure 5. Type Y695AM AssemblyB2650_1

Page 8

Y695A SeriesThe Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fis

Comments to this Manuals

No comments