D100405XENG
Installation Guide
English – May 2002
Type H800
www.emersonprocess.com/regulators
Introduction
This installation guide provides instructions for installation, startup,
and adjustment. To receive a copy of the instruction manual,
contact your local Fisher Sales Ofce or Sales Representative or
view a copy at www.emersonprocess.com/regulators. For further
information refer to: Type H800 Instruction Manual, form 5187,
D100405X012.
P.E.D. Categories
This product may be used as a pressure accessory with
pressure equipment in the following Pressure Equipment
Directive 97/23/EC categories. It may also be used outside
of the Pressure Equipment Directive using sound engineering
practice (SEP) per table below.
PRODUCT SIZE CATEGORIES FLUID TYPE
DN 6 (1/4-inch) SEP 1
Specications
End Connections
DN 6 (1/4-inch) NPT female
Vent Connection
DN 15 (1/2-inch) NPT female
Maximum Allowable Control Pressure
(1)
17,2 bar (250 psig)
Pressure Range
(1)
Non-adjustable, start to discharge between
2,7 and 3,0 bar (39 and 44 psig)
Reseat Pressure
(1)
2,4 bar (35 psig) or higher
Proof Test Pressure
All Pressure Retaining Components have been proof
tested per Directive 97/23/EC - Annex 1, Section 7.4
Material Temperature Capabilities
(1)
-20 to 150°F (-29 to 66°C)
1. The pressure/temperature limits in this installation guide and any applicable
standard or code limitation should not be exceeded.
Installation
Only qualied personnel should install
or service a backpressure regulator.
Backpressure regulators should be installed,
operated, and maintained in accordance
with international and applicable codes and
regulations, and Fisher instructions.
If using a backpressure regulator on a hazardous
or ammable uid service, personal injury
and property damage could occur due to re
or explosion of vented uid that may have
accumulated. To prevent such injury or damage,
provide piping or tubing to vent the uid to a
safe, well-ventilated area or containment vessel.
Also, when venting a hazardous uid, the piping
or tubing should be located far enough away
from any buildings or windows so to not create
a further hazard, and the vent opening should be
protected against anything that could clog it.
Personal injury, equipment damage, or leakage
due to escaping uid or bursting of pressure-
containing parts may result if this backpressure
regulator is overpressured or is installed where
service conditions could exceed the limits given
in the Specications section, or where conditions
exceed any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting devices
(as required by the appropriate code, regulation,
or standard) to prevent service conditions from
exceeding limits.
Additionally, physical damage to the backpressure
regulator could result in personal injury and
property damage due to escaping uid. To avoid
such injury and damage, install the backpressure
regulator in a safe location.
Clean out all pipelines before installation of the backpressure
regulator and check to be sure the backpressure regulator
has not been damaged or has collected foreign material
during shipping. For NPT bodies, apply pipe compound to
the male pipe threads. For anged bodies, use suitable line
gaskets and approved piping and bolting practices. Install
the backpressure regulator in any position desired, unless
otherwise specied, but be sure ow through the body is in
the direction indicated by the arrow on the body.
Note
It is important that the backpressure regulator be
installed so that the vent hole in the spring case is
unobstructed at all times. For outdoor installations,
the backpressure regulator should be located
away from vehicular trafc and positioned so that
water, ice, and other foreign materials cannot enter
the spring case through the vent. Avoid placing
the backpressure regulator beneath eaves or
downspouts, and be sure it is above the probable
snow level.
Overpressure
Maximum inlet pressures depend upon body materials and
temperatures. Refer to the nameplate for the maximum
inlet pressure of the valve. The valve should be inspected
for damage after any overpressure condition. Fisher
backpressure regulators are NOT ASME safety relief valves.
Startup
The backpressure regulator is factory set at approximately the
midpoint of the spring range or the pressure requested, so an
initial adjustment may be required to give the desired results.
With proper installation completed and relief valves properly
adjusted, slowly open the upstream and downstream shutoff
valves (if applicable).
Adjustment
To change the outlet pressure, remove closing cap or loosen
the locknut and turn the adjusting screw clockwise to increase
outlet pressure or counterclockwise to decrease pressure.
Monitor the outlet pressure with a test gauge during the
adjustment. Replace closing cap or tighten the locknut to
maintain the desired setting.