Display
1 Variables
2Device Information
3 DD Revision
Setup & Diag
1 Basic Setup
2 Detailed Setup
3 Display
4 Calibrate
5 Stroke Valve
Alert Record
1 Display Record
2 Clear Record
3 Inst Date & Time
4 Record Group Enab
Detailed Setup
1 Mode
2 Protection
3 General
4 Measured Var
5 Actuator & Valve
6 Response Control
7 Alerts
8 Self Test Shutdown
9 Transmitter/Switches
Expert Tuning Gains
1 Prop Gain
2 Vel Gain
3 MLFB Gain
Burst
1 Burst Enable
2 Burst Command
D103217X012 April 2010
Notes:
This menu is available by pressing the left
arrow key from the previous menu.
Available only if the instrument has a transmitter
and limit switches installed.
See menu 1‐1‐1‐4
See menu 1‐1‐1‐4‐3
Stroke Valve
1 Done
2 Ramp Open
3 Ramp Closed
4 Ramp to Target
5 Step to Target
Online
1 Setup & Diag
2 Analog In
3 Travel
4 Travel SP
5 Drive Sgl
6 Pressure
7 Instrument Status
Self Test Shutdown
1 Flash Rom Fail
2 Temp Comp Fail
3 Ref Voltage Fail
4 Drive Current Fail
5 NVM Fail
6 Temp Sensor Fail
7 Press Sensor Fail
8 Travel Sensor Fail
Calibrate
1 Analog In Calib
2 Auto Calib Travel
3 Manual Calib Travel
4 Pressure Calib
5 Auto Tuner
6 Transmitter Calib
Alerts
1 Travel Alerts
2 Travel Dev Alert
3 Travel Accum Alert
4 Cycle Count Alert
5 Other Alerts
6 Alert Record
Measured Var
1 Analog In Units
2 Input Range Hi
3 Input Range Lo
4 Pressure Units
5 LUI Pressure Units
6 Temp Units
General
1 HART Tag
2 Message
3 Descriptor
4 Date
5 Valve Serial Num
6 Inst Serial Num
7 Polling Address
8 LUI Language
Mode
1 Instrument Mode
2 Control Mode
3 Restart Cont Mode
4 Restart
5 Burst
Auto Setup
1 Setup Wizard
2 Auto Calib Travel
3 Auto Tuner
4 Tuning
Min Open/Close
1 Min Opening Time
2 Min Closing Time
Other Alerts
1 Drive Alert Enab
Device Information
1 HART Univ Rev
2 Device Rev
3 Firmware Rev
4 Firmware Date
5 Main Elec Rev
6 Sec Elec Rev
7 Sensor Serial Num
8 Inst Level
9 Device ID
Limits & Cutoffs
1 Travel Limit Hi
2 Travel Limit Lo
3 Travel Cutoff Hi
4 Travel Cutoff Lo
Travel Alerts
1 Tvl Hi/Lo Enab
2 Tvl HH/LL Enab
3 Tvl Alert Hi Pt
4 Tvl Alert Lo Pt
5 Tvl Alert Hi Hi Pt
6 Tvl Alert Lo Lo Pt
7 Tvl Alrt DB
Travel Dev Alert
1 Tvl Dev Alert Enab
2 Tvl Dev Alert Pt
3 Tvl Dev Time
Variables
1 Temp
2 Cycle Count
3 Tvl Accum
Instrument Status
1 Valve Alerts
2 Failure Alerts
3 Operational Status
4 Display Record
Basic Setup
1 Auto Setup
2 Manual Setup
Actuator & Valve
1 Max Supply Press
2 Actuator Style
3 Valve Style
4 Zero Control Signal
Hot Key
1 Instrument Mode
2 Protection
3 Tuning
Field Communicator
1 Offline
2 Online
3 Frequency Device
4 Utility
Manual Setup
1 Instrument Mode
2 Press & Actuator
3 Tuning & Calib
Response Control
1 Tuning Set
2 Damping Factor
3 Expert Tuning Gains
4 Input Char
5 Custom Char Table
6 Setpt Filter Time
7 Limits & Cutoffs
8 Min Open/Close
9 Integral Settings
1‐1‐1
1‐1‐2
1
7
Travel Accum Alert
1 Tvl Accum Alrt Enab
2 Tvl Accum Alrt Pt
3 Tvl Accum DB
4 Tvl Accum
Cycle Count Alert
1 Cycl Cnt Alrt Enab
2 Cycl Cnt Alrt Pt
3 Cycle Count DB
4 Cycle Count
Field Communicator Menu Tree - DVC2000 Digital Valve Controller
1
Press & Actuator
1 Pressure Units
2 LUI Pressure Units
3 Max Supply Press
4 Actuator Style
5 Valve Style
7 Zero Control Signal
Tuning & Calib
1 Tuning Set
2 Damping Factor
3 Expert Tuning Gains
4 Tvl Cutoff Lo
5 Auto Calib Travel
Integral Settings
1 Enab Int Control
2 Integral Gain
3 Integral Dead Zone
www.Fisher.com
FIELDVUEt DVC2000 Digital Valve Controller
1
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process
Management business division of Emerson Electric Co. Emerson, Emerson Process
Management, and the Emerson logo are trademarks and service marks of Emerson Electric
Co. HART is a mark owned by the HART Communication Foundation. All other marks are
the property of their respective owners.
Tuning
1 Tuning Set
2 Damping Factor
3 Expert Tuning Gains
Record Group Enable
1 Valve Group Enab
2 Failure Group Enab
3 Lim Switch Stat En
Transmitters/Switches
1 Switch 1 Trip Point
2 Switch 1 Closed
3 Switch 2 Trip Point
4 Switch 2 Closed
5 Transmitter Action
2
2
2
2
1‐1‐1‐4
1‐1
1‐2
1‐3
1‐4
1‐5
1‐1‐2‐2
1‐2‐1
1‐2‐3
1‐2‐4
1‐2‐5
1‐2‐6
1‐2‐9
1‐2‐8
1‐3‐1
1‐3‐2
1‐2‐7
1‐2‐6‐7
1‐2‐6‐8
1‐2‐6‐9
1‐2‐7‐1
1‐2‐7‐2
1‐2‐7‐3
1‐2‐7‐4
1‐2‐7‐5
1‐2‐7‐6
1‐2‐7‐6‐4
1‐2‐1‐5
1‐1‐2‐3
Instrument Level HC, AD, and PD
3
3
475 Field
Communicator
EFisher Controls International LLC 2010; All Rights Reserved
Menu Tree applies to:
Device
Revision
DD
Revision
Firmware
Revision
1 1, 2, & 3
Hardware
Revision
1 1
1‐1‐1‐4‐3
4
4
4
TM
www.FIELDVUE.com
For the telephone number of the Emerson Process
Management sales office nearest you, contact:
In North America
Fisher Controls International LLC
1 (641) 754-3011
In Latin America
Fisher Controls International LLC
1 (314) 746-9900
In Asia Pacific
Emerson Process Management
Asia Pacific Private Ltd.
(65) 6777-8211
In Europe
Emerson Process Management Ltd.
+44 1634 895800
For equipment service or support needs, contact your
local Emerson Process Managment sales office.
Page view 0
1 2

Summary of Contents

Page 1 - Menu Tree applies to:

Display1 Variables2 Device Information3 DD RevisionSetup & Diag1 Basic Setup2 Detailed Setup3 Display4 Calibrate5 Stroke ValveAlert Record1 Displa

Page 2

Function/Variable Fast‐Key SequenceActuator Style 1‐1‐2‐2‐4 or 1‐2‐5‐2Alert Record 1‐2‐7‐6Alert Record Group Enable 1‐2‐7‐6‐4Analog Input 2Analog Inpu