Emerson 63EG-98HM Installation Guide

Browse online or download Installation Guide for Unknown Emerson 63EG-98HM. Emerson 63EG-98HM Installation Guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
D102630XUS2
Installation Guide
English – January 2015
Type 63EG-98HM
www.fisherregulators.com
Introduction
This Installation Guide provides instructions for
installation, startup and adjustment. To receive a copy
of the Instruction Manual, contact your local Sales

further information refer to: Type 63EG-98HM Instruction
Manual, form 5475, D102630X012.
P.E.D. Categories



PRODUCT SIZE CATEGORY FLUID TYPE
DN 50 to 150 and 200x150 /

II 1
Specications
Main Valve Body and End Connection Styles
(1)
See Table 2
Maximum Design Pressure
(1)

Body Sizes
Type 63EG-98HM main valve: DN 50, 80, 100, 150

Type MR98H Pilot: DN 15 / 1/2 in.
Maximum Operating Relief (Inlet) Pressure
Including Buildup
(1)(2)

Maximum Outlet Pressure
(1)(2)

Maximum Differential Pressure
(1)

Proof Test Pressure

tested per Directive 97/23/EC - Annex 1, Section 7.4
Relief Set Pressure/Backpressure Control Ranges
(1)(3)



(4)
/

(4)
Differential and Buildup Pressure Requirements
(1)
See Table 1
Temperature Capabilities
(1)
Fluorocarbon (FKM):

Ethylenepropylene (EPR):
Steel: 
Stainless steel: 
Peruoroelastomer (FFKM):
Installation
!
WARNING
Only qualied personnel shall install or
service a relief valve or backpressure
regulator. Relief valve or backpressure
regulator should be installed, operated and
maintained in accordance with international
and applicable codes and regulations and
Emerson Process Management Regulator
Technologies, Inc. instructions.
If using a relief valve or backpressure
regulator on a hazardous or ammable
uid service, personal injury and property
damage could occur due to re or explosion
of vented uid that may have accumulated.
To prevent such injury or damage, provide
piping or tubing to vent the uid to a safe,
well-ventilated area or containment vessel.
Also, when venting a hazardous uid,
the piping or tubing should be located
far enough away from any buildings or
windows so to not create a further hazard
and the vent opening should be protected
against anything that could clog it.
Personal injury, equipment damage or
leakage due to escaping uid or bursting
of pressure-containing parts may result if
this relief valve or backpressure regulator
is overpressured or is installed where
service conditions could exceed the limits
given in the Specications section or
where conditions exceed any ratings of the
adjacent piping or piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation or standard) to prevent
service conditions from exceeding limits.
Additionally, physical damage to the relief
valve or backpressure regulator could result
in personal injury and property damage due
to escaping uid.
To avoid such injury and damage, install the
relief valve or backpressure regulator in a
safe location.
Clean out all pipelines before installation of the relief valve









1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.



Page view 0
1 2 3 4

Summary of Contents

Page 1 - Type 63EG-98HM

D102630XUS2Installation GuideEnglish – January 2015Type 63EG-98HMwww.fisherregulators.comIntroductionThis Installation Guide provides instructions for

Page 2

2Type 63EG-98HMNoteIt is important that the relief valve or backpressure regulator be installed so that the vent hole in the spring case is unobstruct

Page 3

3Type 63EG-98HMFigure 1. Type 63EG Main Valve35A3174-AA28124241526112122112716931201314173 2425Parts ListType 63EG Main ValveKey Description 1 Main

Page 4

Type 63EG-98HM©Emerson Process Management Regulator Technologies, Inc., 2002, 2015; All Rights ReservedThe Emerson logo is a trademark and service mar

Comments to this Manuals

No comments