T HIRD-PART Y MO NIT O R I N G CO NNEC T I VIT Y
The Liebert Monitoring Group can provide multiple paths for
integrating Liebert equipment into your existing Building or
Network Management system. Through strict conformance
to Open Protocols like Modbus, BACnet, SNMP, Liebert can
provide robust and effective integrated solutions.
Building Management System Interfaces
Building Management Systems maintain a vital role
on overall operations or facilities and buildings. Simply
stated, Building Management Systems (BMS) create
and maintain controlled, energy-efficient
environments for all types of premises. This includes
the management and monitoring of core aspects of
each facility, from power supply, temperature, and
humidity, to fire, access and security.
Generally speaking, most BMS systems contain the
ability to communicate to Modbus and or BACnet
devices. These languages or protocols are considered
Open” from the standpoint that they do not require
special tools in order to integrate these devices into a
BMS system.
Supports Modicon’s Modbus and ASHRAE’s BACnet
definitions.
Network Management
System Interfaces
One of the main purposes of deploying a Network
Management System (NMS) is to maintain data
availability. This includes access to data and
applications vital to business critical operation. One of
the key elements of an NMS operation is that devices
or units reside on a network infrastructure. All of the
devices that reside on the network require space and
manageability in order for professionals to successfully
manage the entire network. This implies that network
performance is critical.
Supports SNMP v1, v2c and MIB II structures.
Third Party Interfaces
SiteLink modules integrate 2, 4 or 12 Liebert
units into a single device. The SiteLink
has the ability to stand alone and act as a
Modbus or BACnet slave through either a
EIA-232 or EIA-485 (2-wire or 4-wire)
configurable port. BACnet over IP can be
accomplished by adding a SiteGate. See
the Advanced Monitoring Solution section
for more details.
Output to Building Management Systems
using Modbus and BACnet MSTP.
The Site TPI-E product can be used to
intelligently communicate to non-Liebert
units within your infrastructure. This
allows you to effectively monitor critical
equipment with SiteScan Web. See the
Advanced Monitoring Solutions section
for more details.
Input from non-Liebert units that
use Modbus, BACnet, LonTalk and other
non-standard protocols.
The Liebert IntelliSlot 485 Card w/Adapter
provides SiteScan Web or Building
Management Systems monitoring and
control of your UPS. The card delivers
Modbus or Liebert’s Proprietary protocol
via the EIA-485 port.
The Liebert IntelliSlot Web/485 Card with
Adapter bridges the gap between Network
and Building Management systems with
its ability to communicate to BMS systems
with Modbus, as well as communicating to
NMS systems through SNMP and Web.
All interfaces can operate concurrently.
Output to Building Management Systems
using Modbus over EIA-485.
Output to Network Management Systems
using SNMP and Web.
The Liebert IntelliSlot Web Card
communicates to network Management
Systems SNMP. As the name infers, the
card also produces a Web page which
allows users to get real-time data
through their Internet browser.
Output to Network Management Systems
using SNMP and Web.